The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECPA, PNP, Pulse Input Type, I/O Cable Length for

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXCP1, PROFINET, I/O Cable Length for LEC: Without

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Symbol Size 01 R1/8, Rc1/8 02 R1/4, Rc1/4 03 R3/8, Rc3/8 04 R1/2, Rc1/2 Thread connection Fittings Applicable tubing O.D.

IDF125F-W/150F-W: Water-cooled type T A B 4 x Eyebolt I.D. 25 G S Facility water outlet R3/4 (When symbol-W4 is specified.) Terminal block for power supply Ball valve Facility water outlet R3/4 (When symbol-W5 is specified.) Terminal block for signal F C Q R Y-shaped strainer 3/4 (Accessory) Drain tube Facility water inlet Facility water inlet L R3/4 (When symbol-W4 is specified.)

1 Actuator cable type/length Robotic cable [m] Nil None R8 8*7 R1 1.5 RA 10*7 R3 3 RB 15*7 R5 5 RC 20*7 Nil Housing B bottom*6 Housing B bottom K Body bottom 2 locations Body bottom For details on auto switches, refer to the Web Catalog. 21 Battery-less Absolute Encoder Type Slider Type/Ball Screw Drive LEFS Series Battery-less Absolute (Step Motor 24 VDC) !

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

Temperature N1 P1 Q1 R1 R2 R3 S1 T1 U1 Main valve: Indicator/ Pilot port direction Symbol Nil Without indicator Kalrez Number of auto switches/Mounting position Symbol Nil Without auto switch 2 pcs. 1 pc. 1 pc.

Q1 R1 R2 R3 S1 T1 Kalrez 4079 SS592 SS630 SSE38 1232-70 3310-75 Chemraz Example) XLH-16-XAN1A VMQ FKM for Plasma ULTIC ARMOR U1 UA4640 Produced by Mitsubishi Cable Industries, Ltd.

Leakage rate is measured at room temperature (20 to 30C). Gas permeation This is leakage caused by diffusion through the elastic body seal material. As temperature increases, the diffusion rate increases, and in many cases, becomes greater than surface leakage.

Lead 4: LEY32DC 50 Regenerative resistor area 60 Lead 8: LEY32DB 40 Work load [kg] Work load [kg] Lead 8: LEY32DB 30 40 Lead 16: LEY32DA 20 Lead 16: LEY32DA 20 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] Regenerative resistor area Applicable Motor/Driver * When using the actuator in the Regenerative resistor area, download the AC servo capacity

LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.