SMC Corporation of America
Elite Part Number Search
Search Results "LEY32DC-300M-S1CM18T"

Lead 4: LEY32DC 50 Regenerative resistor area 60 Lead 8: LEY32DB 40 Work load [kg] Work load [kg] Lead 8: LEY32DB 30 40 Lead 16: LEY32DA 20 Lead 16: LEY32DA 20 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] Regenerative resistor area Applicable Motor/Driver * When using the actuator in the Regenerative resistor area, download the AC servo capacity

LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.

SpeedVertical Work Load Graph LEY25l (Motor mounting position: Top/Parallel, In-line) 40 Lead 3: LEY25C 30 Work load [kg] 20 Lead 6: LEY25B 16 Lead 12: LEY25A 10 8 0 0 200 600 1000 1400 Speed [mm/s] LEY32l (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) 50 60 Lead 4: LEY32DC 50 Lead 5: LEY32C 40 46 37 40 Work load [kg] Work load [kg] 30 30 Lead 8: LEY32DB

LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 300mm, Motor Option: None, Rod End Thread: M (Male)

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for

Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed [mm] Model L A B n D E Without lock With lock LEFS40Em-150m 506 555 156 328 4 150 LEFS40Em-200m 556 605 206 378 6 2 300 LEFS40Em-250m 606 655 256 428 6 2 300 LEFS40Em-300m

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32DC-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Dimensions [mm] Model L A B n D E F G H Without lock With lock LEKFS25Em-100m 335.5 380.5 106 210 4 100 45 LEKFS25Em-200m 435.5 480.5 206 310 6 2 240 220 LEKFS25Em-300m 535.5 580.5 306 410 8 3 360 340 LEKFS25Em-400m 635.5 680.5 406 510 8 3 360 340 LEKFS25Em-500m 735.5 780.5 506 610 10 4 480 460 35 14 LEKFS Series Battery-less Absolute (Step Motor 24 VDC) Dimensions: In-line Motor LEKFS32E

(between lead wire and case) Operating time .1.2ms Ambient temperature . 10 to 60C Impact resistance . 300m/s D-A90(V) Contact protection box OUT() Brown [Red] Reed switch CD-P11 OUT( ) Blue [Black] CD-P12 Leakage current . 0 Enclosure . IEC529 standard IP67 (JISC0920) watertight Note) Refer to page 12 for lead wire lengths.

SMC Electronic Switch Series Variations Model Selection Table Self-contained Style ZSE1 ISE1 ZSE2 ISE2 PS1000 PS1100 ZSP1 GS40 ISA ZSE3 ISE3 Model General pneumatic Fluid Calibration method Trimmer calibration 0.1 to 0.45MPa 0.1 to 0.4MPa 0 to 0.98 MPa 101 to 20kPa 0.1 to 0.2MPa (Detection zone 10 to 300m) 0 to 100kPa 0 to 1MPa 101 to 0kPa 0 to 98kPa 0 to 0.98MPa 101 to 0kPa Calibration pressure

When excessive impact (300m/s2 or more) is applied to a reed switch during operation, the contact point will malfunction and generate or cut off a signal momentarily (1ms or less). Consult SMC regarding the need to use a solid state switch depending upon the environment. 7. Do not use in an area where surges are generated.

(between lead wire and case) Operating time 1.2ms Ambient temperature 10 to 60C (14 to 140F) Impact resistance 300m/s Leakage current None Enclosure IEC529 standard IP67, watertight (JISC0920) For a lead wire length of 3m, "L" is shown at the end of the part number.

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 300mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m)

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 300mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: A (10m)

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller: LECPMJ, CC-Link, Direct Input Type, I/O Cable Length: -, Communication Plug Connector