SMC Corporation of America
Elite Part Number Search
Search Results "LEY32DB-100C"

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

40 Work load [kg] Work load [kg] Lead 8: LEY32DB 30 40 Lead 16: LEY32DA 20 Lead 16: LEY32DA 20 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] Regenerative resistor area Applicable Motor/Driver * When using the actuator in the Regenerative resistor area, download the AC servo capacity selection program/SigmaJunmaSize+ from the SMC website.

LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.

SpeedVertical Work Load Graph LEY25l (Motor mounting position: Top/Parallel, In-line) 40 Lead 3: LEY25C 30 Work load [kg] 20 Lead 6: LEY25B 16 Lead 12: LEY25A 10 8 0 0 200 600 1000 1400 Speed [mm/s] LEY32l (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) 50 60 Lead 4: LEY32DC 50 Lead 5: LEY32C 40 46 37 40 Work load [kg] Work load [kg] 30 30 Lead 8: LEY32DB

LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32DB-150, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: DIN rail mounting type

Bending value (Reference) 20 Complies with FDA (Food and Drug Administration) 177-1550 Operating temperature Air, Inert gas: 20 to 200C, Water: 0 to 100C (No freezing) dissolution test.

Heater assembly quantity 200/40 200/50 400/100 600/150 800/220 1200/350 100V H4 100C Heater assembly quantity used Heater power W (Nominal value) In-rush/Power consumption (Option symbolOperating voltage) 800/40 800/50 1600/100 2400/150 3200/220 4800/350 200V 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs. 3 pcs. 4 pcs.

None H0 High temp. type With heater for 80C (176F) H1 5 to 150C (41 to 302F) H2 With heater for 100C (212F) H3 With heater for 120C (248F) Option specifications/Combination table Option specifications Symbol Model XLF-16 XLF-25 XLF-40 XLF-50 XLF-63 XLF-80 A Indicator H0 Without heater High temp. type H1 With heater for 80C (176F) H2 With heater for 100C (212F) H3 With heater for 120C (248F

None H0 High temp. type With heater for 80C (176F) H1 5 to 150C (41 to 302F) H2 With heater for 100C (212F) H3 With heater for 120C (248F) Option specifications/Combination table Option specifications Symbol Model XLF-16 XLF-25 XLF-40 XLF-50 XLF-63 XLF-80 A Indicator H0 Without heater High temp. type H1 With heater for 80C (176F) H2 With heater for 100C (212F) H3 With heater for 120C (248F

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

One-touch fittings, Insert fittings Fluoropolymer fittings: LQ series Note 3) Applicable Note 2) fittings Miniature fittings: M, MS series (Hose nipple type) 20C 0.7 0.25 0.1 Refer to the max. operating pressure curve. 1 0.4 0.2 0.7 0.25 0.1 1 0.4 0.2 1.5 0.55 0.3 1.7 0.6 0.3 2.3 0.85 0.4 100C Max. operating pressure (MPa) 200C How to measure the minimum bending radius.

-X7 Angle adjusting screw "B" Angle adjusting screw "A" Rotation at 90 Heat resistant In this rotary actuator, the material of the seals has been changed to the heat resistant type (to withstand up to 100C), for applications in environments that exceed the standard specification temperatures of 0 to 60C.

End plate Symbol 12 -X2128 Heat-resistant Specification (10 to 100C) Seal material and grease have been changed so that the product can be used at temperatures between 10 up to 100C. Specifications Ambient temperature 10C to 100C (No freezing) Seal material Fluororubber MXQ X2128 Standard model no.