SMC Corporation of America
Elite Part Number Search
Search Results "LEY32C-30M-S1"

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: CE1 (JXCE1, EtherCAT®), I/O Cable Length for LEC: Without

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type), I/O Cable Length for LEC

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXCE1, EtherCAT®, I/O Cable Length for LEC: Without Cable, Controller Mounting

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC: 1.5m, Controller Mounting

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM LE ELECTRIC ACTUATOR, ACTUATOR, 32MM LE ELECTRIC ACTUATOR, 10.83176 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY32PPPPPPPPPPP20 to 500

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM LE ELECTRIC ACTUATOR, ACTUATOR, 32MM LE ELECTRIC ACTUATOR, 10.83176 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY32PPPPPPPPPPP20 to 500

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.

S1 U T2 T2 U [mm] Size S1 T2 U 63 84 142 4 Note) When the motor is mounted on the left or right side in parallel, the groove for auto switch on the side to which the motor is mounted is hidden. 504 Electric Actuator/Rod Type LEY Series AC Servo Motor Dust-tight/Water-jet-proof (IP65 Equivalent) * Select options Dimensions: In-line Motor LEY63D Encoder Z-phase detecting position 41 LEF Rod

U S1 [mm] Size S1 T2 U 25 47 91 1 32 61 117 1 63 84 142 4 T2 T2 Note) When the motor is mounted on the left or right side in parallel, the groove for auto switch on the side to which the motor is mounted is hidden. 742 Electric Actuator/Rod Type LEY Series AC Servo Motor 25, 32, 63 Size Dimensions: In-line Motor Encoder Z-phase detecting position F1 LEF Rod operating range Note 1) (Stroke

U S1 [mm] Size S1 T2 U 25 47 91 1 32 61 117 1 63 84 142 4 U T2 T2 Note) When the motor is mounted on the left or right side in parallel, the groove for auto switch on the side to which the motor is mounted is hidden. 858 Electric Actuator/Rod Type LEY Series Motorless Type 25, 32 Size Refer to the Motor Mounting on page 873 for details about motor mounting and included parts.

Kit/Electrical entry/Cable length F P Kit (Dsub connector) Kit (Flat cable connector) Connector location Top (vertical) Side (horizontal) Connector location Top (vertical) Side (horizontal) P .1.10-40 P .1.10-36 Without cable Without cable S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 stations Max.16 (2) Max.16 (2) F kit P kit P kit F kit With cable (1.5m) With cable (3m) With cable (5m

Ambient & Fluid Temperature -10 ~ 50C A Clean Room version is available to specified Lubrication Not Required order please contact your local SMC Sales Office Manual Override Non-Locking Push Type Shock Resistance/Vibration Resistance 150 / 30m/s2 for further information. Mounting Orientation Free The VQD1000 is used either on a Single SubEnclosure Dust Proof base or Manifold Mounted.

Large diameter piping Small diameter nozzle S1 Pressure loss: Small With nozzle S2 Effective area ratio 2:1 6 Pump capacity Previous rate Pressure Pump head (electric power) Pressure loss: Small P Pump outlet Nozzle outlet Discharge rate Main Points Improve pressure loss. Improve the effective area ratio with the upstream side by using a small diameter nozzle.