Your search for LEY32 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 8 hits in the keyword search.
Product Information » New Products Search Results
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
Regenerative resistor area Work load [kg] Work load [kg] 30 Lead 10: LEY32B 40 Lead 20: LEY32A 20 Lead 20: LEY32A 20 10 0 0 0 200 400 600 800 1000 1200 1400 0 200 400 600 800 1000 1200 1400 Speed [mm/s] Speed [mm/s] LEY32DV7 (Motor mounting position: In-line) Vertical Horizontal 60 80 Lead 4: LEY32DC Lead 4: LEY32DC 50 Regenerative resistor area 60 Lead 8: LEY32DB 40 Work load [kg] Work
SpeedHorizontal Work Load Graph LEY25l (Motor mounting position: Top/Parallel, In-line) 70 Lead 3: LEY25C 60 Lead 6: LEY25B LEF 50 Work load [kg] 40 LEJ LEL Lead 12: LEY25A 20 LEM 0 LEY 0 200 600 1000 1400 Speed [mm/s] LES LEY32l (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 5: LEY32C Lead 10: LEY32B Lead 4: LEY32DC LER 60 60 Lead 8
(mm) Color Symbol N R BU B Translucent Red (Translucent) Blue (Translucent) Black (Opaque) Inch nominal size Inch nominal size 5/32" 5/16" Operating Temperature: Max. 200C It varies depending on the operating pressure. Refer to the graph for the maximum operating pressure.
Features PFA Super PFA Modified PTFE FEP Material Chemical resistance 260C 260C 260C 200C Heat resistance Flexibility Ion elution Internal smoothness Air, Water, Inert gas Fluid Chemical liquids, Deionized water Chemical liquids, Deionized water 4 to 19 2 to 25 4 to 12 4 to 12 Tubing O.D.
Bending value (Reference) 20 Complies with FDA (Food and Drug Administration) 177-1550 Operating temperature Air, Inert gas: 20 to 200C, Water: 0 to 100C (No freezing) dissolution test.
Heat resistance:200C It changes according to the operating pressure.
Table symbols : Can be used Compatibility is indicated for fluid temperatures of 200C or less. Consult SMC regarding fluids other than the above. Consult SMC regarding operating conditions.
Proof pressure D 0 to 150C Nut material PVDF Operating temperature MS 0 to 200C Nut material PFA LQ Withstand Pressure and Heat Resistance Performance Precautions MQR 4.0 T Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions. 3.5 3.0 Piping Caution 2.5 Pressure (MPa) 1.
Up to 215psi @ 200C. NO Cold-Flow Loosening of Compression Nuts Unique locking mechanism and tapered mounting surfaces. Swept Flow Path No reduction in i.d., and high conductivity. High Side-Loading Trapezoidal thread and tubing strain relief coupled for high-resistance. Changing Tube Diameters Fast & Easy Within each body size, a range of tube sizes available.
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: L (Foot), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length for LEC: 3 (
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 3m, Controller