Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange), Actuator Cable Length: A (10m), Controller Type (LEC, JXC): 6N (LECA6, Step Data Input Type, NPN), I/O Cable Length for LEC: w/o Cable, Controller Mounting: D (DIN Rail Mounting), Communication
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Actuator Cable Length: 10m, Controller Type (LEC, JXC): LECA6, Step Data Input Type, NPN, I/O Cable Length for LEC: w/o Cable, Controller Mounting: DIN Rail Mounting, Communication Plug Connector
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE E210 & N320 1.117 LINEAR ACTUATOR: COMPACT CYLINDER NCQ2/CQ2 D I M E N S I O N S ( M M) LARGE BORE STANDARD DOUBLE ACTING SINGLE ROD SERIES (N)CQ2 Bore B CQ2 NCQ2 D E F NCQ2 i K L M N OB Q RB S Stroke (mm) CQ2 J CQ2 NCQ2 RA U Orifice A Size C C H H OA OA 125 83 30 36 142 24.5 190 32 16 114
IDFB4E to 15E 1.6 [40] Air Flow Capacity 2.36 [60] IDFB4E Model IDFB3E IDFB6E IDFB8E IDFB11E D Circuit breaker 5 SCFM (8 m3/h) 13 SCFM (23 m3/h) 17 SCFM (29 m3/h) 19 SCFM (32 m3/h) 23 SCFM (39 m3/h) Air flow capacity (ANR) A C Conditions: Inlet air pressure: 100 psi (0.7 MPa), Inlet air temperature: 100F (37.8C), Outlet air temperature: 50F (10C), Ambient temperature: 100F (37.8C) B E Power
1/2 26 (45) 25 (43) 28 (47) 43 (74) 41 (70) 45 (77) NPT 3/4 R134a (HFC) 100F (37.8C) 100 psi (0.7 MPa) 62 (106) 59 (100) 65 (110) P. 90 to 96 80 (136) 71 (120) 86 (147) NPT 1 120 (205) 107 (182) 130 (221) NPT 11/2 173 (294) 161 (273) 181 (308) R407C (HFC) 258 (438) 226 (384) 297 (504) NPT 2 353 (600) 300 (510) 406 (690) Note) Air flow capacity for each dew point is indicated. 2.
IDFA 100F 40 For use in Europe Nil C G K R V Size Size 100F 125F 150F Option Voltage Symbol Note) Description Symbol Voltage Nil C G K R V None Three-phase 400 VAC (50 Hz) 40 Anti-corrosive treatment for copper tube With Chinese labels and a Chinese operation manual Moderate pressure specification (1.6 MPa) With a circuit breaker With a timer controlled solenoid valve type auto drain Note
Refrigerant R134a (HFC) IDU E IDF 100F 30 W Water-cooled Nil C G K P R V 4 5 Size Size Air compressor size *1 Piping direction 100F 100 kW 125F 125 kW 150F 150 kW Symbol Description 4 Facility water piping direction: Right *1 Refrigerant R407C (HFC) IDU E 5 Facility water piping direction: Left *1 *1 Note that the above values are for reference only.
(37.8C) 100 psi (0.7 MPa) 100F (37.8C) IDFB80 247 (420) 314 (534) 353 (600) R2/ NPT2 IDFB90 335 (570) 406 (690) 459 (780) *1 Select port sizes when ordering the products.
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY25DC-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY25DC-150, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Heatless Desiccant Compressed Air Dryers Series IDW Features -40F dew point standard, -100F optional Suitable for global installation 12~24VDC or 100~240VAC Vertical or horizontal mounting Designed for simple service with desiccant canisters Intelligent electronic processor Specifications Inlet flow rate Dimension inch Weight (lbs) Dryer configuration Dryer model Pipe size B C A scfm
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange)
Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable
Driver Driver Servo amplifier Servo amplifier or MR-D01 or MR-D01 24 V DC 24 V DC DOCOM (DOCOMD) DOCOM (DOCOMD) Control output signal Control output signal RA RA For source output interface For sink output interface Use a noise filter, etc. to minimize the influence of electromagnetic interference.
FLW ADJMNT,BOTTOM PIPNG 100F/R, No.DescriptionModel 1Body6For bottom piping Flow adjustment valve assembly(with pin)For 100 l/minZS-33-11NL