Your search for LEY25 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)
Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -,
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male)
Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data
Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 5.56667 lb, ModelStroke [mm]Product weight [kg]Step motorServo motorLEY25D301.461.42
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 5.56667 lb, ModelStroke [mm]Product weight [kg]Step motorServo motorLEY25D301.461.42
Example) LEY25DB-100 for the LEY25DB-100BMU-R16N1D-X5 Stroke Model 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Please consult with SMC for non-standard strokes as they are produced as special orders. Conrm that the combination of the controller/driver and the actuator is correct.
Example) LEY25DB-100 for the LEY25DB-100BMU-R16N1D-X5 Stroke Model 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Please consult with SMC for non-standard strokes as they are produced as special orders. Confirm that the combination of the controller/driver and the actuator is correct.
1 series 10C 20C 30C Standard model (Normal operation) Set dew point Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 10 to 30C. 2. Normal operation (ECO LED is OFF): Dew point is fixed to 10C. Description No.
Given an ambient temperature at 86F (30C) and a relative humidity 60%. 1. Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102psi (0.7 MPa). 3.
Given an ambient temperature of 30C and a relative humidity of 60%. Trace the arrow mark, from point A of ambient temperature 30C to obtain the intersection B on the curved line for the relative humidity of 60%. Trace the arrow mark, from the intersection B to obtain the intersection D on the curved line for the 0.7 MPa pressure characterisitics.
This system Your system Communication data TEMP PV 30C TEMP PV TEMP PV 30C TEMP SP 30C External communication 30C Discharge temp: OFFSET 1C 31C dissipation: Heat 1C Circulating fluid temp. in your system: 30C Figure 8-7 When MODE3 is selected HRW Series 8.4 Offset Function 8-11 HRX-OM-K003 Chapter 8 Appendix 8.5 BAND/READY function Sets BAND to TEMP SP value, and notifies TEMP PV value reaches
1 series 10C 20C 30C Standard model (Normal operation) Set dew point Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 10 to 30C. 2. Normal operation (ECO LED is OFF): Dew point is fixed to 10C. Description No.