Your search for LEY25 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type)
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O
Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 1.5m
Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 3m, Controller
Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Model L A B n D E Without lock With lock LEFS32Em-50m 332 384 56 180 4 LEFS32Em-100m 382 434 106 230 4 LEFS32Em-150m 432 484 156 280 4 LEFS32Em-200m 482 534 206 330 6
T0425B-500X3 Available 150m for 10, 200m for 8, 500m for 4 and 6. Contact SMC for other lengths. Suffix -X3 to the end of part number. Ex.)
W hen a current of approx. 150m AD C or m ore i s appl i ed, t he over current ci rcui t i s archi ved, Er. 5 i s di spl ayed and t he operat i on st ops. Pl ease use w i t h i nst al l i ng t he l oad t hat t he out put current becom es t o 80m AD C or l ess.
ZB-OM00201-B Specifications General Specifications Ambient -5 to 50oC (No condensation) temperature range Fluid Air, inert gas Vibration 30m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 1) 20m/s2 (With switch) Impact 150m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 2) 100m/s2 (With switch) Note 1)
Specifications General Specifications -5 to 50oC (Without pressure sensor and pressure switch, With pressure switch, Ambient temperature range With pressure switch with energy saving function) (No condensation) 0 to 50oC (With pressure sensor) Fluid Air 30m/s2 (Without pressure sensor and pressure switch, With pressure sensor) Vibration resistance Note 1) 20m/s2 (With pressure switch) 150m
Specifications General Specifications -5 to 50oC (Without pressure sensor and pressure switch, With pressure switch) 0 to 50oC (With pressure sensor) Ambient temperature range 5 to 50oC (With pressure switch with energy saving function) (No condensation) Fluid Air 30m/s2 (Without pressure sensor and pressure switch, With pressure sensor) Vibration resistance Note 1) 20m/s2 (With pressure switch) 150m
TU0425B-500X3 Available 150m for 10, 200m for 8, 500m for 4 and 6. Contact SMC for other lengths. Suffix -X3 to the end of part number. Ex.) TIUB01Y-100X3 Consult SMC in case of 16. 2.4-3