The cooling capacity will be reduced by 300W when option T and MT [High head pump] are selected. 5 Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. is lower than 10oC. 6 Outlet temp. when the circulating fluid flow is rated flow, and the circulating fluid outlet and the return are directly connected.

Applicable model HRR012/018/024/030-A/W-T1 Rated flow50/60Hz*1 L/min 10 (0.28MPa) Maximum pump head Pump 50/60Hz*2 m 40 Output W 400 Circuit protector A 15 Recommended earth leakage breaker capacity A 15 The cooling capacity reduces about 300W from the value in the catalog.

Facility water temp. 25 1500 Cooling capacity[W] 1500 25 Cooling capacity[W] 32 32 35 35 1000 1000 500 500 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T1 is selected.

Vertical work load [kg] 30 30 20 20 Lead 6: LEY25AB 15 Lead 3: LEY25AC 12 10 10 Lead 12: LEY25AA Lead 6: LEY25AB 7 6 Lead 12: LEY25AA 3 0 0 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] Graph of Allowable Lateral Load on the Rod End (Guide) 100 [Stroke] = [Product stroke] + [Distance from the rod end to the center of gravity of the workpiece] LEY32/40 F Load

005: 500W 007: 750W Heat Exchanger 9.1.2 Manufacturing code indication H E D 0 0 7 H W 13 > Recirculating fluid tube size 13: 1/2X3/8 19: 3/4X5/8 > Cooling method W: Water-cooled > Product name H: Heat Exchanger > Cooling capacity 003: 300W 005: 500W 007: 750W SERIAL No.

30 11 LZ 10 LC3F2 20 Lead 6: LEY25AB Lead 6: LEY25B 15 5 10 Lead 12: LEY25AA Lead 12: LEY25A 7 2 0 0 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] 229 LEY-X5 Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Dust-tight/Water-jet-proof (IP65 Equivalent) Force Conversion Graph Step Motor (Servo/24 VDC) Servo Motor (24 VDC) LEY25 LEY25 500 140 Lead 3: LEY25AC

in cae of option: T Fig 9.4-1 Cooling capacity(HRS018-A-20-R) 9.4.2 HRS030-A-20--R The cooling capacity will be reduced by 300W in case of option: T.

The cooling capacity will be reduced by 300W when option T and MT [High head pump] are selected. 5 Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. is lower than 10oC. 6 Outlet temp. when the circulating fluid flow is rated flow, and the circulating fluid outlet and the return are directly connected.

The cooling capacity will be reduced by 300W when option T [High pressure pump] are selected. 4 Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. is lower than 10 oC. 5 Outlet temp. when the circulating fluid flow is rated flow, and the circulating fluid outlet and the return are directly connected.

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY25AC-50, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY25AC-400, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: DIN rail mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY25AC-150, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

method Cooling/heating automatic shift PWM control Cooling / Heating method Thermoelectric device (Thermo-module) Liquid Tank Water-cooled Radiating method Controller Forcible air-cooled Operating temp. range -15.0 to 60.0oC (5oC or more for water) (Note 1) (Note 5) Temp. stability 0.01oC (Note 1) Temp. distribution 0.02oC (Note 1) Cooling capacity 140W (Water) (Note 2) Heating capacity 300W

Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.

(Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1. Number of step data (Points) I/O cable length [m] 2 2 stroke end points/ 12 intermediate points (Programless) Nil Without cable 1 1.5 3 3 5 5 Parallel I/O type N NPN P PNP The controller is sold as single unit after the compatible actuator is set.

Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.