Your search for LEY25 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: CD1 (JXCD1, DeviceNetâ„¢), I/O Cable Length for LEC: Without
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXCD1, DeviceNetâ„¢, I/O Cable Length for LEC: Without Cable, Controller
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Lead 3: LEY25C 60 Lead 6: LEY25B LEF Regeneration Option Models 50 Work load [kg] Size Model LEY25 LEC-MR-RB-032 LEY32 LEC-MR-RB-032 LEY63 Lead 12: LEY25A LEJ 40 Area where the regeneration option is required.
SpeedWork Load Graph (Guide) for Step Motor (Servo/24 VDC) LECP6, LECP1, LECPMJ Horizontal Vertical LEY25m LEY25m for acceleration/deceleration: 2000 mm/s2 80 35 Lead 3: LEY25C 70 30 Lead 3: LEY25C Horizontal work load [kg] 29 Vertical work load [kg] 50 55 60 Lead 6: LEY25B 20 40 Lead 6: LEY25B 15 Lead 12: LEY25A 30 10 20 7 10 Lead 12: LEY25A 0 0 0 300 200 400 100 500 600 0 300 200 400 100
U S1 [mm] Size S1 T2 U 25 47 91 1 32 61 117 1 63 84 142 4 T2 T2 Note) When the motor is mounted on the left or right side in parallel, the groove for auto switch on the side to which the motor is mounted is hidden. 742 Electric Actuator/Rod Type LEY Series AC Servo Motor 25, 32, 63 Size Dimensions: In-line Motor Encoder Z-phase detecting position F1 LEF Rod operating range Note 1) (Stroke
Lead 6: LEY25B 300 Force [N] LEH 200 LEY -X5 100 11LEFS Lead 12: LEY25A Step 2 Check the lateral load on the rod end.
Large diameter piping Small diameter nozzle S1 Pressure loss: Small With nozzle S2 Effective area ratio 2:1 6 Pump capacity Previous rate Pressure Pump head (electric power) Pressure loss: Small P Pump outlet Nozzle outlet Discharge rate Main Points Improve pressure loss. Improve the effective area ratio with the upstream side by using a small diameter nozzle.
LC1-1-S1 PC-98 (MS-DOS) LC1-1-W1 (Windows 95 Japanese) LC1-1-W2 (Windows 95 English) and LC1-1-R (dedicated communication cable) (Refer to pages 194, 195, and 199.) or LC1-1-T1(Teaching box) are required.
M There are currently 3 versions available: version 1 products (V1.m or S1.m), version 2 products (V2.m or S2.m), and version 3 products (V3.m or S3.m). Keep in mind that in order to write a backup file (.bkp) to another controller with the JXC-BCW, it needs to be the same version as the controller that created the file.
50m AB Z 1 2 21() 22 1 2 3 4 5 (4) /3 1 2 PI-PID master-slave () () 24 ( :J4 :J3 :) LECSS2-T LECSS-S(3) J4 J3 1 2 STO Tough Drive Tough Drive Tough Drive 3 16 (2) (2) SSCNET SSCNET/H J4/J3(5) 25 1.
Program P1 P2 P3 P16 S1 S1 S1 S1 S2 S2 S2 S2 Step S32 S32 S32 S32 Following are CEU2s special feature: 1. Predictive Control & Learning Function (Allow High Repeatability and Precision, 0.5mm) With learning function, after every execution, brake point will be amended, according to the deviation of stopping position from setting position.
P16 s1 s1 s1 s1 s2 s2 s2 s2 ... ... ... ... s32 s32 s32 s32 0.5mm) 1 2 , 2. 30mm 30mm 3.
Program P1 P2 P3 P16 S1 S1 S1 S1 S2 S2 S2 S2 Step S32 S32 S32 S32 Following are CEU2s special feature: 1. Predictive Control & Learning Function (Allow High Repeatability and Precision. 0.5mm) With learning function, after every execution, brake point will be amended, according to the deviation of stopping position from setting position.
Exhaust NVFR4400 NVFR4410 % 2.8 180 70 or less 1.S1 (0.73) center 1h 2.8 Pressure NVFR4500 NVFR451 0 % 3.S 180 70 or less 1.S1 (0.73) center 1h 3.S The Agures lIated are without subplate.
Refer to section 11.5 for the wire used for the extension cable. 10m or less 2m 50m or less MR-BKS1CBL2M-A1-L MR-BKS1CBL2M-A2-L MR-BKS1CBL2M-A1-H MR-BKS1CBL2M-A2-H 50m LE-CSBExtension cable (To be fabricated) () Servo motor MR-BKS2CBL03M-A1-L MR-BKS2CBL03M-A2-L (5) LE-CSB24VDC power Electoromagnetic (Note4) Trouble (4) Supply for lock Brake(MBR) DC24V (Note3) (MBR) (3) (ALM) (MBR) AWG20