SMC Corporation of America
Elite Part Number Search
Search Results "LEY25A-200-1P"

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type), I/O Cable Length for LEC

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC: 3m, Controller

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEPY LEPS LEY25m LEY25m for acceleration/deceleration: 2000 mm/s2 LER 35 80 70 Lead 3: LEY25C 30 LEH Horizontal work load [kg] Vertical work load [kg] 60 Lead 3: LEY25C LEY -X5 50 20 40 Lead 6: LEY25B 11LEFS Lead 6: LEY25B 16 30 10 8 11LEJS 20 18 12 Lead 12: LEY25A Lead 12: LEY25A 10 25A0 0 0 300 200 400 100 500 600 0 300 200 400 100 500 600

SpeedWork Load Graph (Guide) for Step Motor (Servo/24 VDC) LECP6, LECP1, LECPMJ Horizontal Vertical LEY25m LEY25m for acceleration/deceleration: 2000 mm/s2 80 35 Lead 3: LEY25C 70 30 Lead 3: LEY25C Horizontal work load [kg] 29 Vertical work load [kg] 50 55 60 Lead 6: LEY25B 20 40 Lead 6: LEY25B 15 Lead 12: LEY25A 30 10 20 7 10 Lead 12: LEY25A 0 0 0 300 200 400 100 500 600 0 300 200 400 100

250 1400 125 1400 63 1400 11 300 1600 150 1600 75 1600 12 350 1800 175 1800 88 1800 13 400 2000 200 2000 100 2000 14 450 2500 225 2500 113 2500 15 500 3000 250 3000 125 3000 LEY25A / LEYG25A LEY25B / LEYG25B LEY25C / LEYG25C Speed [mm/s] Acceleration Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] [mm/s2] 0 18 200 9 200 5 200 1 24 300 12 300 7 300 2 36 400 18 400 9 400

350 1800 175 1800 88 1800 13 400 2000 200 2000 100 2000 14 450 2500 225 2500 113 2500 15 500 3000 250 3000 125 3000 57 No.JXC-OMU0004-A LEY25A LEYG25A LEY25B LEYG25B LEY25C LEYG25C 2] 2] 2] [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s 0 18 200 9 200 5 200 1 24 300 12 300 7 300 2 36 400 18 400 9 400 3 48 500 24 500 12 500 4 60 600 30 600 15 600 5 72 700 36 700 18 700 6 84 800 42 800 21 800 7 100

12: LEY25A 20 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] LEY32lV7 (Motor mounting position: Top/Parallel) Vertical Horizontal 50 80 Lead 5: LEY32C Lead 5: LEY32C 40 60 Lead 10: LEY32B Regenerative resistor area Work load [kg] Work load [kg] 30 Lead 10: LEY32B 40 Lead 20: LEY32A 20 Lead 20: LEY32A 20 10 0 0 0 200 400 600 800 1000 1200 1400 0 200

Lead 6: LEY25B 300 Force [N] LEH 200 LEY -X5 100 11LEFS Lead 12: LEY25A Step 2 Check the lateral load on the rod end.

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type)

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC: -, Controller

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY25A-100, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: DIN rail mounting type

Note 3) Refer to page 200 for dimensions of A or B port top-ported type.

Manifold Options 200 SY3000/5000/7000 Series Manifold Parts Nos.

N.C. 3.2 4 6 8 10 12 16 1P, 2A, 3R 1/8, 1/4 VP(A)300 X M5 1P, 2A, 3R 1/4, 3/8 VP(A)500 X 1/8 N.O. 1P, 2A, 3R 3/8, 1/2 VP(A)700 1. Remove the body from the sub-plate and reset the H mark on the body corresponding to the N.O. mark on the sub-plate as shown in the figure above. 2.

rate: 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.

CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 140 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 1000 mm 160 180 200 0 100 200 300 400 500 600 700 800 900 1000 Average speed [mm/s] ZK2 Combination Manifold Fittings, Replacement Parts, Tools Manifold Options Specific Product Precautions * Values at extension of a directly coupled cylinder when meter-out speed