Your search for LEY16 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Model L A B n D E Without lock With lock LEFS32Em-50m 332 384 56 180 4 LEFS32Em-100m 382 434 106 230 4 LEFS32Em-150m 432 484 156 280 4 LEFS32Em-200m 482 534 206 330 6
Teaching box (with 3 m cable) Equipment for input setting data of controller 49 Step Motor Controller (Servo/24 VDC) Series LECP6 How to Order LE C P 6 N Actuator Actuator part number Controller (Except cable specifications and actuator options) Example: Enter [LEHZ10LK2-4] for LEHZ10LK24AF-R16N1 Compatible motor P Step motor (Servo/24 VDC) Option Number of step data Nil D Note) Screw mounting
Size: 16, Motor Mounting Position: D (In-line Type), Motor: A [Servo Motor (24 VDC)], Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: M (Male)
Size: 16, Motor Mounting Position: In-line Type, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for
Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LESH8RJ-50 for the LESH8RJ-50B-R16N1.
RoHS Programless Controller Series LECP1 How rder C 1 LE N 1 P LEHZ10LK2-4 I/O cable length [m] Actuator part number Controller Nil 1 3 5 Without cable 1.5 3 5 (Except cable specifications and actuator options) Example: Enter [LEHZ10LK2-4] for LEHZ10LK2-4AF-R16N1 Compatible motor P Step motor (Servo/24 VDC) Number of step data (Points) When placing an order for the controller with an actuator
Teaching box (with 3 m cable) Equipment for input setting data of controller 49 Step Motor Controller (Servo/24 VDC) Series LECP6 How to Order LE C P 6 N Actuator Actuator part number Controller (Except cable specifications and actuator options) Example: Enter [LEHZ10LK2-4] for LEHZ10LK24AF-R16N1 Compatible motor P Step motor (Servo/24 VDC) Option Number of step data Nil D Note) Screw mounting
T0425B-500X3 Available 150m for 10, 200m for 8, 500m for 4 and 6. Contact SMC for other lengths. Suffix -X3 to the end of part number. Ex.)
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16DAC-100, I/O cable length / communication plug(m): 3, Controller/driver mounting method: DIN rail mounting type
Size: 16, Motor Mounting Position: D (In-line Type), Motor: A [Servo Motor (24 VDC)], Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type),
Size: 16, Motor Mounting Position: In-line Type, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for
W hen a current of approx. 150m AD C or m ore i s appl i ed, t he over current ci rcui t i s archi ved, Er. 5 i s di spl ayed and t he operat i on st ops. Pl ease use w i t h i nst al l i ng t he l oad t hat t he out put current becom es t o 80m AD C or l ess.
Actuator part number Controller (Except cable specifications and actuator options) Example: Enter LER10K-2 for the LER10K-2L-R16N1. Compatible motor P Step motor (Servo/24 VDC) Option Number of step data (Points) Nil D Note) Screw mounting DIN rail mounting I/O cable length [m] 6 64 Nil 1 3 5 Without cable 1.5 3 5 Note) DIN rail is not included. Order it separately.
Electric equipment Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LEHZ10LK2-4 for the LEHZ10LK2-4AF-R16N1.
Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.
Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1.