Your search for LEY16 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Piston speed Note 3) Supply pressure 0.1MPa 300cm/min or less 200cm/min or less 150cm/min or less Total allowable leakage Supply pressure 0.3MPa 1200cm/min or less 1000cm/min or less 800cm/min or less Supply pressure 0.5MPa 3000cm/min or less 2000cm/min or less 1500cm/min or less Note 1) Use clean, dry air with no freezing. Note 2) Refer to precautions on page 21 regarding lubrication.
Description Standard Brass 5cm3/ min or less 50cm 3/ min or less 150cm 3/ min or less (1) (1) (2) PTFE Body Stainless steel q Note 1) Differ from the operating condition of pressure. Note 2) Heat loss at 0.5 MPa is about 5kcal/h. Note 3) Value on option "V", "M" (Non-leak, vacuum).
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male)
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: A (10m), Controller Type - LEC, JXC: CE1 (JXCE1, EtherCAT®)
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 10m, Controller Type - LEC, JXC: JXCE1, EtherCAT®, I/O Cable Length for LEC: Without
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication
Temperature N1 P1 Q1 R1 R2 R3 S1 T1 U1 Main valve: Indicator/ Pilot port direction Symbol Nil Without indicator Kalrez Number of auto switches/Mounting position Symbol Nil Without auto switch 2 pcs. 1 pc. 1 pc.
CQ2 series Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A B + Stroke S2 L B + Stroke S1 L B + Stroke S2 L L B + Stroke S1 A + Stroke (S1 + S2) A + Stroke (S1 + S2) Note) In the case of bore sizes 12 to 25 with auto switch, port directions are different.
Q1 R1 R2 R3 S1 T1 Kalrez 4079 SS592 SS630 SSE38 1232-70 3310-75 Chemraz Example) XLH-16-XAN1A VMQ FKM for Plasma ULTIC ARMOR U1 UA4640 Produced by Mitsubishi Cable Industries, Ltd.
CDRBU2W10, 15-S CDRBU2W20, 30-S CRB2 CRBU2 CRB1 2 x S2 2 x S1 2 x S1 MSU 2 x S2 CRJ Rotary actuator CRA1 CRQ2 2 x S1 2 x S1 2 x S1 2 x S1 Rotary actuator MSQ (34.5: Connector type) MSZ A port B port CRQ2X MSQX 2 x R A port B port 2 x R MRQ 1 Auto switch Auto switch 2 5 20.5 (26.5: Connector type) 1.