Product Information » New Products Search Results
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 250mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC:
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 250mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Body Bottom Tapped, Actuator Cable: -, Actuator Cable Length: -, Controller: -, I/O Cable Length: -, Communication Plug Connector: -, Controller Mounting: -
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 250mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Body Bottom Tapped, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller: PNP Controller, I/O Cable Length: 3m, Communication Plug Connector: None, Controller
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 5.55564 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
SpeedWork Load Graph (Guide) For Servo Motor (24 VDC) LECA6 Horizontal Vertical LEY16Am LEY16Am 15 15 Lead 2.5: LEY16AC Horizontal work load [kg] 12 12 Vertical work load [kg] 9 9 8 Lead 2.5: LEY16AC Lead 5: LEY16AB 6 6 Lead 5: LEY16AB 4 Lead 10: LEY16AA 3 3 Lead 10: LEY16AA 2 0 0 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEY25Am LEY25Am 40 40 Horizontal
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AB-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: DIN rail mounting type
250C 1/4, 3/8 500 Super Mist Separator 350C Color change indicates when element is saturated.
Thread type Port size Symbol Nil Type Symbol Size 150C Applicable body size 250C 350C 450C 550C Rc G*1 01 02 03 04 06 10 F N 1/8 1/4 3/8 1/2 3/4 1 NPT *1 Conforms to ISO1179-1. 90-AM650/850 90 AM 650 10 Series compatible with secondary batteries Option Description IN-OUT reversal direction R Symbol Nil 90 Material restriction Body size Accessory Applicable compressor output (guide) Symbol
Hex. 12 * Based on 250C (77F) 1MPa = 145PSI T E C H N I C A L SPECIFICATIONS DIGITAL PRESSURE SWITCH WITH REMOTE SENSOR DIAGRAM Hex. 10 Gasket reducer M O R E H O W T O O R D E R S E E N E X T P A G E When installing indicators next to each other, allow 20mm between units. Minimum separation 65mm between centres. Courtesy of Steven Engineering, Inc. !
Hex. 12 * Based on 250C (77F) 1MPa = 145PSI T E C H N I C A L SPECIFICATIONS DIGITAL PRESSURE SWITCH WITH REMOTE SENSOR DIAGRAM Hex. 10 Gasket reducer M O R E H O W T O O R D E R S E E N E X T P A G E When installing indicators next to each other, allow 20mm between units. Minimum separation 65mm between centres. Courtesy of Steven Engineering, Inc. !
Body Size: 250C [17SCFM (500l/Min), Approx. Compressor Output 5HP, (3.7kW)], Thread: Rc, Port Size: 02 (1/4), Accessory: None, Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: Standard, Air Pressure: Standard, Drain Guide: J (Drain Guide 1/4 Female Threaded), IN-OUT Direction: Standard, Pressure Switch 125VAC, 30VDC: None, Element Service Indicator: T (Yes)
Body Size: 250C [17SCFM (500l/Min), Approx. Compressor Output 5HP, (3.7kW)], Thread: Rc, Port Size: 02 (1/4), Accessory: B (Bracket), Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: Standard, Air Pressure: Standard, Drain Guide: J (Drain Guide 1/4 Female Threaded), IN-OUT Direction: Standard, Pressure Switch 125VAC, 30VDC: None, Element Service Indicator: T (Yes)
This is a legacy product, and replaced byCP96SB50-250C, CYL, PROFILE, ISO, ACTUATOR, C95/C96 TIE-ROD CYLINDER, ND, 50MM C95/CP95 DOUBLE-ACTING, 3.32898 lb