SMC Corporation of America
Elite Part Number Search
Search Results "LEY16AA-50M"

Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length

Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length

Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 5m, Controller

Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

SpeedWork Load Graph (Guide) For Servo Motor (24 VDC) LECA6 Horizontal Vertical LEY16Am LEY16Am 15 15 Lead 2.5: LEY16AC Horizontal work load [kg] 12 12 Vertical work load [kg] 9 9 8 Lead 2.5: LEY16AC Lead 5: LEY16AB 6 6 Lead 5: LEY16AB 4 Lead 10: LEY16AA 3 3 Lead 10: LEY16AA 2 0 0 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEY25Am LEY25Am 40 40 Horizontal

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: NPN, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-150, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: NPN, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-100, I/O cable length / communication plug(m): 3, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

output NPN or PNP open collector (same as switch output) Illuminates up when output is ON OUT1: Green; OUT2: Red 1 sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode Note 6): 3-digit fixed 12 to 24 VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no freezing and condensation) 1000 VAC for 1 min. between external terminal and case 50M

output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M

output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M

Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Model L A B n D E Without lock With lock LEFS32Em-50m 332 384 56 180 4 LEFS32Em-100m 382 434 106 230 4 LEFS32Em-150m 432 484 156 280 4 LEFS32Em-200m 482 534 206 330 6

Dimensions [mm] Model L1 L2 A B C D E F G J K 138 LEPS10m-25m 152.5 20 22 30 29 20 29 39 88.2 61.8 LEPS10m-50m 163 177.5 24 43 34 50 24 50 60 113.2 LEPS10Lm-25m 124 138.5 20 22 30 29 20 29 39 88.2 47.8 LEPS10Lm-50m 149 163.5 24 43 34 50 24 50 60 113.2 19 Series LEPY/LEPS Specific Product Precautions 1 Be sure to read before handling.