The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type), I

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC:

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -,

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

SpeedWork Load Graph (Guide) For Step Motor (Servo/24 VDC) LECP6, LECP1, LECPMJ Horizontal Vertical LEY16m LEY16m for acceleration/deceleration: 2000 mm/s2 10 40 Lead 2.5: LEY16C 35 Horizontal work load [kg] Lead 2.5: LEY16C 8 Vertical work load [kg] 30 15 17 20 23 25 Lead 5: LEY16B 5 Lead 5: LEY16B 4 Lead 10: LEY16A 10 6 2 Lead 10: LEY16A 5 0 0 0 300 200 400 100 500 600 0 300 200 400 100

50W 1 0 0.02 Ground ball screw 50W High rigidity direct acting guide 600 0.05 Rolled ball screw 50W Standard motor [Tamagawa Seiki Co., Ltd.] 0.1 1 5 100W 500 Slide screw 0.1 20 200W 300 Slider guide Without brake Non-standard motor 0.02 Ground ball screw 100W Matsushita Electric Industrial Co., Ltd.

50W 100W 100W 50W 50W 100W 100W 12mm lead 20mm lead 12mm lead 8mm lead 12mm lead 20mm lead 12mm lead 8mm lead Horizontal specification Work load kg 5 10 Vertical specification 600 500 Horizontal specification Maximum speed mm/s 600 400 Vertical specification 0.05 0.02 0.1 AC servomotor (50W) AC servomotor (100W) with brake 12mm, 12mm lead 12mm, 12mm lead 20mm, 20mm lead Rolled ball screw

50W 100W 100W 50W 50W 100W 100W 12mm lead 20mm lead 12mm lead 8mm lead 12mm lead 20mm lead 12mm lead 8mm lead Horizontal specification Work load kg 5 10 Vertical specification 600 500 Horizontal specification Maximum speed mm/s 600 400 Vertical specification 0.05 0.02 0.1 AC servomotor (50W) AC servomotor (100W) with brake 12mm, 12mm lead 12mm, 12mm lead 20mm, 20mm lead Rolled ball screw

A B C D 43 44 Non-standard Motor Series LJ1H10 High Rigidity Direct Acting Guide Motor Output Ground Ball Screw 50W 12mm/12mm lead Horizontal Mount How to Order Stroke 1 LJ1H10 G PB 1 F W X10 Cable entry direction Top entry Left entry Motor specification Switch Cable entry direction Power supply voltage Matsushita Electric Industrial Co., Ltd.

a <> ABSINC ABS() / / INC()/ / b c 2mm d e f / P.41 7.2 / P.43 7.2 g INP ON INP INP ON / P.41 7.2 h / P.41 7.2 / P.42 7.2 i 100 % 150 % LEY16A 200 % LEY25A / P.42 7.2 j 12AREA ON 12 INC ABS() No.1 148 250 AREA k INP No.0 50+20 = 70 -24- 1 -IN INPAREA a b c d e f g h i j k No. 1 2 mm/s mm mm/s^2 mm/s^2 % % mm/s % mm mm mm 0 ABS 100 100.00 3000 3000 0 0 0 100 80.00

Mitsubishi Electric Corporation Yaskawa Electric Corporation Nil G R Y Brake 50W 100W 200W 1 2 3 None With brake Nil K Power supply voltage Stroke 100/110VAC 50/60Hz 100/115VAC 50/60Hz 200/220VAC 50/60Hz 200/230VAC 50/60Hz Without motor Lead screw lead 1 H B C F A D E 8mm 12mm 20mm 5mm 10mm 25mm 40mm 2 0 Lead screw type The tables above show the definition for each symbol only and cannot

1H LJ1H101B LJ1H202A LJ1H202C LJ1H303D LJ1S101SC LJ1S202SC LJ1S303SE LJ1H101SC LJ1H202SC LJ1H303SC LJ1H102H-K LJ1H102B-K LJ1H202F-K LJ1H202A-K LJ1H303A-K Ball screw High rigidity direct acting guide Without brake 100W 2H 200W 50W 100W 200W 50W 100W 200W 100W 100W 100W 100W 200W 3H 1S 2S 3S 1M 2M 3M 1VH Note 1) Slide screw Slider guide Slide screw High rigidity direct acting guide Ball screw

Mitsubishi Electric Corporation Yaskawa Electric Corporation Nil Bottom Motor output G R Y Stroke 50W 1 2 3 100W 200W Lead screw lead 20mm C Power supply voltage Slide screw S Lead screw type 100/110VAC 50/60Hz 100/115VAC 50/60Hz 200/220VAC 50/60Hz 200/230VAC 50/60Hz 1 The tables above show the definition for each symbol only and cannot be used for actual model selection. 2 Without motor

LERH30K-3LLERH30K-3 0 (a) ) LEY16RA-75LEY16RALEY16RA-100 (b) LEFSH LEFS ) LEFSH25RH-300LEFS25RH-300LEFS25RH-300 (c) 11-)(25A-) 11-25A-11-25A) 11-LEFSH16A-100BRLEFS16A-100LEFS16A-100 15 No.SFOD-OMT0009CN-B Execute (Apply) 3.6 (2) 16 No.SFOD-OMT0009CN-B (2) 7. 512 2048 / 0 1 0 1 1 4 1 4 11 () 12 () 1 2 1 11 [] 14096 1 LEY16C-300 2.5mm 1/1 2 LEY16B-300 5mm 25/50 3 LEY16A

[Setting example] Axis Actuator Lead Electronic gear ratio Axis 1 LEY16C 300 2.5mm 1 / 1 Undefined No.12 1 to 4096 X Axis 2 LEY16B-300 5mm 1 / 2 Axis 3 LEY16A-300 10mm 1 / 4 Adjust the electronic gear ratio in order to travel the same distance per pulse of the axis with the shortest lead (Axis 1).

) LEY16RA-75 LEY16RALEY16RA-100 (b) LEFSH() LEFS ) LEFSH25RH-300 LEFS25RH-300LEFS25RH-300 (C) (11-)(25A-) 11-25A-11-25A) 11-LEFSH16A-100BR LEFS16A-100LEFS16A-100 -15No.JXC-OMT0001CN-C Execute()Execute Check box Execute Apply Apply 3.6 (2) -16No.JXC-OMT0001CN-C (2) 9. 512 2048 / 0 1 0 1 1 4 1 4 11 12 1 2 1 [] 11 1 4096 1 LEY16C-300 2.5mm 1/1 2 LEY16B-300 5mm 25/50 3 LEY16A