Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied. T unit Can be connected with PLC I/O card for serial transmission. EX300-TMB1For models of Mitsubishi Electric Corp. EX300-TTA1For models of OMRON Corp. EX300-TFU1For models of Fuji Electric Company Ltd.
MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, 2 occupied stations Connect to the I/O card of transmission PLC manufacturers to enable serial transmission. EX300-TMB1for Mitsubishi Electric Corporation EX300-TTA1.for OMRON corporation EX300-TFU1.for Fuji Electric Co., Ltd. EX300-T001.
No. of output points, 16 points Master station: PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations Stations are counted from station 1 on the D side.
MB 50 10% 30% 70% 300 50% Stroke mm AS2201F -02-10 200 100 50% 30% 10% 70% 0 400 MB 63 300 Stroke mm AS3201F -03-10 200 100 0 ANA1 -C12 T1075 400 MB 80 300 Stroke mm AS4000-03 200 100 0 400 MB 100 300 Stroke mm 200 AS4000-04 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details
200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 200 300 400 500 600
EX300-T001General purpose MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output point, 16 points No. of sta. occupied, 2 stations Each T unit has 32 control points.
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied.
A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo
EX300-TMB1For models of Mitsubishi Electric Corporation EX300-TTA1For OMRON EX300-TFU1For Fuji Electric EX300-T001General purpose T units have 32 control points per unit No. of output points, 16 points Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points).
Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations T unit Can be connected with PLC I/O card for serial transmission.
LECSA LEFS25 LEFS32 LEFS40 Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Parameter Para No Initial value Recommended value Number of command input pulses per revolution *3 PA05 100 100 Electronic gear numerator *3 PA06 1 100(Positioning mode: 10) Electronic gear denominator *3 PA07 1 20 12 6 24 16 8 30 20 10 Feel length multiplication (STM) (Multiplier) PE02 0 0(Less
L8 = 16n + 118.5 100 Drawing shows a SC case.
L8 = 16n + 118.5 100 Drawing shows a SC case.
dual 3-port valve Operating pressure range Internal pilot operating pressure range (MPa) 0.1 to 0.7 (High pressure type: 0.1 to 1) 100 kPa to 0.7 (4-position: 100 kPa to 0.6) 100 kPa to 0.7 (High pressure type: 100 kPa to 1) 2-position single 2-position double 3-position External pilot operating pressure range (MPa) Pilot pressure range 0.25 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to
32 40 S2 100 25 LECSA-S1 R Right side parallel AC servo motor S3 200 32 LECSA-S3 Incremental L Left side parallel S4 400 40 LECSA2-S4 encoder Lead[mm] LECSB2-T5 Symbol LEKFS25 LEKFS32 LEKFS40 LECSC2-T5 T6 100 25 LECSN2-T5H 20 24 30 LECSS2-T5 A 12 16 20 LECSB2-T7 B 6 8 10 AC servo motor LECSC2-T7 T7 200 32 Absolute encoder LECSN2-T7Stroke LECSS2-T7 50 50 LECSB2-T8 to to LECSC2-T8 T8 400 40
Specification 1.1 LECS series driver 1.1.1 How to order L E S Y H 16 D S2 A 50 S 2 A1 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (3)Motor type (2)Motor mouting position (1) Size Symbol type Output D In-line 16 25 Size Compatible driver [W] R Right side parallel AC servo motor LECSA-S1 LECSA-S3 S2 100 16 L Left side parallel S3 200 25 (Incremental encoder) LECSB2-T5 LECSC2-T5 LECSS2-T5 T6 100
100 25 LECSA -S1 S3 200 32 LECSA -S3 S4 400 40 LECSA2-S4 Motor option Stroke [mm] 100 25 LECSB -S5 LECSC -S5 LECSS -S5 Motor mounting position S6 Nil Without option B With lock 100 100 to to 1000 1000 Refer to the applicable stroke table.
to 100 kPa 100 kPa 100 kPa Positive pressure 0 to 1 MPa 0 1 MPa Low pressure 0 to 101 kPa 101 kPa 0 For general purpose fluids Compound pressure 100 to 100 kPa 100 kPa 100 kPa Positive pressure 0 to 500 kPa 0 500 kPa 16-3-24 3 Compact Pressure Sensor For General Air Series PSE540 How to Order ZSE ISE Pressure sensing range PSE 1 3 Vacuum (0 to 101 kPa) Compound pressure (100 to 100 kPa)