SMC Corporation of America
Elite Part Number Search
Search Results "LERH10K-3L-R5"

or ring type, size 4, 22-16 AWG) NVFR4000, SOOO: 1.2S-3.SM, 1.2SY-3L, 1.25Y-3M e(+. -) indicate the direction of DC solenoid valve with light or with surge voltage suppressor.

EVS Applicable terminal: 1.25-3.5M, 1.25Y-3L, 1.25-3M Although A, B+ and B marks are indicated on the terminal block, VFR5000 can be used as either +COM or COM.

VS4 Terminal block marking AC and 100 VDC or more Applicable terminal: VFS3000: 1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S VFS4000: 1.25-3.5M, 1.25Y-3L, 1.25Y-3M VFS5000: 1.25-4, 1.25-4M VFS6000: 1.25-3.5M, 1.25Y-3L, 1.25-3M There is no polarity. Tightening torque for terminal: 0.6 Nm Non plug-in type (With terminal) Remove cover (1), over terminal block (2) attached to the inside of body.

Applicable terminal: VFS3000: 1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S VFS4000/5000/6000: 1.25-3.5M, 1.25Y-3L, 1.25Y-3M There is no polarity.

Internal torque control mode Position control mode Position control mode Internal speed control mode PD07 *DI3-1 Input signal device selection 3L (CN1-5) 0D06h Refer to Any input signal can be assigned to the CN1-5 pin. The devices that can be assigned and the setting method are the same as in parameter No. PD03. the name and function field. Select the input device of the CN15 pin.

/symbol/ Setting mode digit Function name [unit] P S T PD07 *DI3L Input device selection 3L Any input device can be assigned to the CN1-17 pin. When "_ _ _ 1" is set in [Pr. PA03] and absolute position detection system by DIO is selected, the CN1-17 pin will become ABSM (ABS transfer mode). _ _ x x Position control mode Device selection 04h Refer to table 5.10 in [Pr.

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: 3 (External Stopper: 90°), Motor Cable Entry: L (Entry on the Left Side), Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5)

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: External Stopper: 90°, Motor Cable Entry: Entry on the Left Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length

(OPEN During Alarm) Approx. 800W Approx. 1200W Signal 1000 1000 (Circulating fluid flow rate 3L/min) (Circulating fluid flow rate 3L/min) Facility water temp. 20deg.C 7 Output Cutoff Alarm Common External 500 15 9 500 Circulating fluid Water, Ethylene glycol solution up to 20% temperature Circulating fluid Facility water temp. 35deg.C 8 Output Cutoff Alarm b contact The compatibility of

Cooling capacity (Set temperature 25C and ambient temperature 25C) Approx. 200W Approx. 400W Approx. 510W Approx. 800W Approx. 1000W (Flow rate 3L/min) (Flow rate 3L/min) (Flow rate 3L/min) (Flow rate 4L/min) (Flow rate 4L/min) Circulating fluid Water, Ethylene glycol solution up to 20% The compatibility of equipment is the responsibility of the person Tank capacity Approx.1.3L who designs

(800) 526-7661 Parallel Run LTees 3/8 7/16 1/4 5/16 5/16 1/4 5/16 1/4 8 T1-L1-1 T4-L4-4 T3-L3-3 T2-L2-2 Parallel Run Reducing LTees 3/8 5/16 5/16 5/16 3/4 15/16 5/16 5/16 5/16 5/16 5/16 5/16 1/4 1/4 MEM 27/32 5/8 5/8 3/4 9 RT3-2L-2 RT3-2L-3 RT4-3L-4 RT1-3L-1 RT3-1L-1 RT2-3L-2 1 11/16 Crosses 1/2 15/16 5/16 5/16 11/16 15/16 MEM 1/4 27/32 1 1 33/64 5/8 15/16 3/8 11/16 1 1/8 1/4 5/8 27/32

Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 piping adapter ZS-46-N1 NPT1/8 piping adapter ZS-46-N2 7 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20

. *2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Nil Without lead wire Symbol Description M5 female thread ZS-46-A1 ZS-46-3L M5 Lead wire with connector (3-core, 2 m lead wire) A1 Bracket A (Vertical mounting) Piping port L Without waterproof cover R1/8 ZS-46-A2 01 * For the lead wire with M12 connector, refer to p. 38.

The manual lever (1.6 x 35l, tip part: M1.6 x 0.35 x 3l) is included with the cylinder. If additional manual levers are required, use the following part number to place an order: CXS06-48BK2777 (for all series). 8-29-19 20 Series CXS Construction: Slide Bearing CXSM6 q e r u !

temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 8 L/min Approx.900W(water), 600W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 8 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN HT-135 Fluorinert FC-77, FC-3283) Recirculating fluid Reservoir capacity : Approx.3L

If a higher flow rate is supplied, the cooling and heating capacity will be slightly affected, but a flow rate of lower than 3L/min will impair the cooling and heating capacity significantly. Be sure to avoid operating the product without cooling water or with cooling water at extremely low flow rates.

Applicable terminal: 1.25-3.5M, 1.25-3L, 1.25-3M Lead Wire Connection Plug-in type (With terminal block) Remove junction cover for sub-plate (1), depress levers(3) of terminal block assembly (2), pull out terminal block assembly. Terminal block assembly is marked as below. Connect it to power supply side. Caution Ground Terminal No. Internal w iring 1 Sol. A side 2 Sol.

Construction/Dimensions (mm) R Note 2) F Note 1) PA M MD MM LA L C HB B HA W Model A CY1B 6 12 M3 x 0.5 x 3l 15 17 6.3 11 35 18 10 2.5 CY1B10 17 M3 x 0.5 x 3l 15 38 18 25 9.5 26 10 2.5 CY1B15 4 25 M3 57 25 M4 x 0.7 6.5 23 16 35 5.5 16.5 6 36 CY1B20 27 4 30 M4 x 0.7 M3 66 18 36 6.5 5.5 17 23.5 6 37 CY1B25 36 M5 x 0.8 M4 5 30 46 8.0 21 28.5 70 47 20 5.5 7 CY1B32 M5 6 47 M6 x 1.0 9.5

Or for applications in which a pneumatic speed controller suffices (3l/min).

0.2% of full span Repeatability Within 0.5% of full span Linearity Within 1% of full span Note 3) Bleed port: 9.5l/min (ANR) or less (supply pressure: 1.0MPa) Exhaust port: 2l/min (ANR) or less (at maximum set pressure) Bleed port: 9.5l/min (ANR) or less (supply pressure: 1.0MPa) Exhaust port: 2l/min (ANR) or less (at maximum set pressure) 4l/min (ANR) or less (supply pressure: 1.0MPa) 3l