SMC Corporation of America
Elite Part Number Search
Search Results "LER50J-2L-S5CP17"

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: JXCP1, PROFINET, I/O Cable Length for LEC: w/o Cable, Controller Option: Screw Mounting, Communication Plug Connector

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: L (Entry on the Left Side)

Oscillation Angle A: [180°] External Stopper, Torque (Range)(N⋅m): 6 to Less than 10, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 6.6, Size: 50, Motor cable entry direction: Entry on the left side, Actuator cable type: Without cable, Actuator

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LER50J-1, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LER50J, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: DIN rail mounting type

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Entry on the Left Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller: Step Data Input Type, PNP, I/O Cable Length: 1.5, Communication Plug Connector: -, Controller Option: -

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Entry on the Left Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller: Step Data Input Type, PNP, I/O Cable Length: 3, Communication Plug Connector: -, Controller Option: -

SMCs series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design.? A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc.? Rotation angle is possible up to 320 (310 on LER10).? Up?to 6.6 N?m of rotation torque (3.3 N?m of pushing torque available).? The rotation speed of

PF2A711 PF2A721 PF2A751 Air, Nitrogen Model Measured fluid Flow rate measurement range Set flow rate range Flow rate measuring range Minimum set unit 0.5 to 10.5l/min 0.5 to 10.5l/min 1 to 10l/min 0.1l/min 0.1l/pulse 2.5 to 52.5l/min 2.5 to 52.5l/min 5 to 50l/min 0.5l/min 0.5 l/pulse 5 to 105l/min 5 to 105l/min 10 to 100l/min 1l/min 1l/pulse 10 to 210l/min 10 to 210l/min 20 to 200l/min 2l

Model No.HRLE090-20/40 * This pump capacity is flow rate of CH1 when flow rate of CH2 is 2L/min. Fig. 6-1 Pump capacity diagram (standard product) Model No.HRLE090-20/40-P * This pump capacity is flow rate of CH1 when flow rate of CH2 is 2L/min.

Internal torque control mode Position control mode Position control mode Internal speed control mode PD05 *DI2-1 Input signal device selection 2L (CN1-4) 0202h Refer to Any input signal can be assigned to the CN1-4 pin. The devices that can be assigned and the setting method are the same as in parameter No. PD03. the name and function field. Select the input device of the CN14 pin.

New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer

nl Pfir20f{f t, -2, -3 t40.2 t45-3 illA (L{t}frt33rl.5 9.5 29.8 30.5 8/.0 5.3 fl/A x/ato.g P | 25iltI l, -2, -3 t40.2145.3 N/A (MR M36 , r.5 9.5 29.0 30.5 87.0 ).J r.r/A N/A 33.0t6.0 Pfl2Zonr t, -2, -3 207.0 2l?.0 t/A (|'lr) n33,1.5 9.5 ?

If the product is under no or light load, it is operational at approx. 1 to 2L/min of facility water. *10: The rated flow is a required flow rate to maintain cooling capacity and temperature stability.

PD03] for settings. x x _ _ For manufacturer setting 02h PD05 *DI2L Input device selection 2L Any input device can be assigned to the CN1-16 pin. _ _ x x Position control mode Device selection 00h Refer to table 5.10 in [Pr. PD03] for settings. x x _ _ Speed control mode Device selection 21h Refer to table 5.10 for settings.

PF2A711 PF2A721 PF2A751 Air, Nitrogen Model Measured fluid Flow rate measurement range Set flow rate range Flow rate measuring range Minimum set unit 0.5 to 10.5l/min 0.5 to 10.5l/min 1 to 10l/min 0.1l/min 0.1l/pulse 2.5 to 52.5l/min 2.5 to 52.5l/min 5 to 50l/min 0.5l/min 0.5 l/pulse 5 to 105l/min 5 to 105l/min 10 to 100l/min 1l/min 1l/pulse 10 to 210l/min 10 to 210l/min 20 to 200l/min 2l

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, NC, 50MM LE ELECTRIC ACTUATOR

SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design.  A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc.  Rotation angle is possible up to 320° (310° on LER10).  Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available).  The rotation speed

Select piping length and size in order to have a recirculating fluid flow more than 2L/min. If the flow is less than 2L/min the temperature stability will be poor. The product may be damaged from continually changing between cooling and heating. 6-3 Operation 6.2 Wiring 6.2.1 Power supply The power supply shall be connected with supplied power supply cable.

2 80 3.14 100 4 0.16 0.16 NCRB50 2.64 3.38 0.77 1.55 0.47 0.98 1.18 M6x1x10 NPT 1/8 0.79 0.12 0.39 0.51 0.20 0.53 1.34 1.97 0.20 0.20 NCRB80 3.74 4.06 0.93 2.11 0.67 1.18 1.77 M8x1.25x13 NPT 1/4 1.42 0.12 0.51 0.63 0.20 0.75 1.57 2.75 0.28 0.28 NCRB100 4.92 4.92 1.18 2.56 0.98 1.77 1.97 M10x1.5x13 NPT 1/4 1.57 0.16 0.75 0.87 0.20 1.10 1.97 3.15 Model Bracket No Includes NCRB50 CRB50-Y-1 2L