Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Option: 7 (Screw Mounting)
Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Option: 8 (DIN Rail Mounting)
Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 5 (5)
Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable Length for LEC: w/o Cable, Controller Option: 7 (Screw Mounting)
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: LECP1, Programless Type, NPN, I/O Cable Length for LEC: 5, Controller Option: -, Communication Plug Connector or I/
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: Screw Mounting, Communication
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: DIN Rail Mounting,
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: 5, Controller Option: -, Communication Plug Connector or I/
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 180°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: JXCP1, PROFINET, I/O Cable Length for LEC: w/o Cable, Controller Option: Screw Mounting, Communication Plug Connector
Oscillation Angle A: [180°] External Stopper, Torque (Range)(N⋅m): 6 to Less than 10, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 6.6, Size: 50, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, NC, 50MM LE ELECTRIC ACTUATOR, 9.47987 lb
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
2 2 Unit name Part no. of each product W-AREA1 0.00 0.00 0.00 W-AREA2 0.00 0.00 0.00 ORG Correct 0.00 0.00 0.00 Sensor type 1 1 1 Option set1 1 1 1 Undefined parameter11 1 1 1 Undefined parameter12 1 1 1 LER Return to origin parameter default Model LER10K LER10J LER30K LER30J LER50K LER50J ORIG direction 2 2 2 Return to origin parameter default ORIG mode 1 1 1 ORIG limit 50 50 50 ORIG time
MR-J3BAT USB D/A CN4 I/F ( ) CN1A CN1 B CN5 CN 3 ( 2 ) I/O USB 1.LECSS-S5 2.
INSTALLATION 2 1 to 2 6 2.1 Installation direction and clearances . 2 3 2.2 Keep out foreign materials . 2 4 2.3 Cable stress . 2 5 2.4 Inspection items . 2 5 2.5 Parts having service lives . 2 6 3.
INSTALLATION 2 1 to 2 6 2.1 Installation direction and clearances . 2 2 2.2 Keep out foreign materials . 2 3 2.3 Cable stress . 2 4 2.4 SSCNET cable laying. 2 4 2.5 Inspection items . 2 6 2.6 Parts having service lives . 2 6 3.