SMC Corporation of America
Elite Part Number Search
Search Results "LEKFS40EB-300B"

)] Stroke 4 [2] 2 [4] (142) [Origin] Note 4) Origin Note 3) 65 6.5 30 79 Motor cable (2 x 5) 60 46.8 Motor option: With lock Step motor Servo motor 7.5 M4 x 0.7 thread depth 8 (F.G. terminal) Cable length y 250 (194) 65 15 15 20 20 24 20 5H9 depth 5 ( ) 0.030 0 24 20 Lock cable (3.5) n x 5.5 [mm] 6 Model L 582 634 682 734 782 834 882 934 982 1034 1082 1134 A B n D E LEFS32;-300 LEFS32;-300B

Lead 10: LEKFS40EB Work load: W [kg] Work load: W [kg] 50 40 20 Lead 20: LEKFS40EA 30 Lead 30: LEKFS40EH Lead 20: LEKFS40EA Lead 30: LEKFS40EH 20 10 10 0 0 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] 5 Model Selection LEKFS Series Battery-less Absolute (Step Motor 24 VDC) SpeedWork Load Graph (Guide) For Battery-less Absolute (Step Motor 24 VDC),

When an analog output unit or analog input unit is connected to Slot 0, and channel 0 needs to be changed to analog range 4-20mA. 3) Select Channel0 (Sub Index 01) from the Slot _AnalogRange (Index 300B) folder.

Note No intermediate bracket is attached to IZS30-300B (SB), IZS30-780B (SB)). Intermediate bracket A. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.

Please contact us for the latest version.sales@ocaire.com, CL1TF140-300B, ACTUATOR, CL1 TIE-ROD CYLINDER, UD, 140MM CL1 DOUBLE-ACTING, .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CLLocked-up cylinderCL1Double acting, Single rodApplicable to ?125 to 160999

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 300

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: Battery-less absolute, 24VDC, Step, Lead: Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 300, Motor Option: -, Seal Band Stopper: -, Actuator Cable Type, Length: -, Controller: -, Controller Mounting: -, Communication Plug Connector, I/O Cable: -

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 350, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R3 (3), Controller: CE1 (JXCE1, EtherCAT®, Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 150, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 7 (Screw Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 150, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: CE1 (JXCE1, EtherCAT®, Direct Input Type), Controller Mounting: 7 (Screw Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 300, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 600, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 600, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: CP1 (JXCP1, PROFINET, Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 600, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: C61 (JXC61, Parallel I/O), Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 300, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 7 (Screw Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 200, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R1 (1.5), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 700, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: CP1 (JXCP1, PROFINET, Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: Battery-less absolute, 24VDC, Step, Lead: Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 300, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: 5, Controller: JXC91, EtherNet/IPâ„¢ Direct Input Type, Controller Mounting: DIN Rail Mounting, Communication Plug Connector

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: Battery-less absolute, 24VDC, Step, Lead: Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 600, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: 5, Controller: JXC91, EtherNet/IPâ„¢ Direct Input Type, Controller Mounting: DIN Rail Mounting, Communication Plug Connector

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: Battery-less absolute, 24VDC, Step, Lead: Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 600, Motor Option: with Lock, Seal Band Stopper: Standard, Actuator Cable Type, Length: 5, Controller: JXCP1, PROFINET, Direct Input Type, Controller Mounting: DIN Rail Mounting, Communication Plug Connector, I/O