3 T6 LEY 25 200 B 2 S2 S w Motor mounting position q Size e Motor type 25 32 63 Symbol Type Output [W] Actuator size Compatible driver Nil Top mounting R Right side parallel L Left side parallel D In-line T6 AC servo motor (Absolute encoder) 100 25 LECSS2-T5 T7 200 32 LECSS2-T7 T8 400 63 LECSS2-T8 For motor type T6, the compatible driver part number sufx is T5. r Lead [mm] t Stroke [mm]
C2 LECSC2-T9/CC-Link Absolute encoder 200V230V S2 LECSS2-T9/SSCNET/H Absolute encoder 200V230V N2 LECSN2-T9/Without network card Absolute encoder 200V240V E2 LECSN2-T9-E/EtherCAT Absolute encoder 200V240V 92 LECSN2-T9-9/EtherNet/IP Absolute encoder 200V240V *If you select with driver, the cable is included. Please select the cable type and length.
Driver: S (SSCNET III Type, Absolute Encoder), Power Supply Voltage: 2 (200 to 230 VAC, 50/60 Hz; for LECSC2-T), Motor Type: T8 [AC Servo Motor (T8), 400W, Absolute Encoder]
Size: 80, Motor Mounting Position: RL (Rear, Left), Motor Type: T8 (AC Servo w/ Absolute encoder, 400W output, LECS compatible), Lead (mm): D (1/3 reduction: LET80: 43.33, LET100: 80), Stroke: 2000mm, Motor Option: B (with Lock), Cable Type: R (Robotic Cable), Cable Length: 2 (2m), Driver Type: C2 (200-230V, LECSC2-T_), I/O Cable Length: 1 (1.5m)
Size: 80, Motor Mounting Position: RL (Rear, Left), Motor Type: T8 (AC Servo w/ Absolute encoder, 400W output, LECS compatible), Lead (mm): L (1/5 reduction: LET80: 26, LET100: 48), Stroke: 2000mm, Motor Option: B (with Lock), Cable Type: R (Robotic Cable), Cable Length: 2 (2m), Driver Type: C2 (200-230V, LECSC2-T_), I/O Cable Length: 1 (1.5m)
Size: 80, Motor Mounting Position: FR (Right), Motor Type: T8 (AC Servo w/ Absolute encoder, 400W output, LECS compatible), Lead (mm): M (1/9 reduction: LET80: 14.44, LET100: 26.67), Stroke: 1500mm, Motor Option: Nil (without option), Cable Type: S (Standard Cable), Cable Length: 5 (5m), Driver Type: C2 (200-230V, LECSC2-T_), I/O Cable Length: Nil (without cable)
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: C (5mm), Stroke: 150mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: L (Foot), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: C2 (LECSC2/CC-Link,
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: A (20mm), Stroke: 50mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: C2 (LECSC2/CC-Link
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: A (20mm), Stroke: 50mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: C2 (LECSC2/CC-Link
, Flexible Cable), Cable Length: A (10m), Driver Type: C2 (LECSC2-T, 200~230V Absolute, CC-Link)
Cable, Flexible Cable), Cable Length: A (10m), Driver Type: C2 (LECSC2-T, 200~230V Absolute, CC-Link)
Cable), Cable Length: A (10m), Driver Type: C2 (LECSC2-T, 200~230V Absolute, CC-Link)
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: 5mm, Stroke: 150mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Foot, Cable Type: Standard Cable, Cable Length: 5m, Driver Type: LECSC2/CC-Link, (Absolute Encoder, I/O
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: 20mm, Stroke: 50mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Rod Flange, Cable Type: Standard Cable, Cable Length: 5m, Driver Type: LECSC2/CC-Link, (Absolute Encoder
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: 20mm, Stroke: 50mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Rod Flange, Cable Type: Standard Cable, Cable Length: 5m, Driver Type: LECSC2/CC-Link, (Absolute Encoder
Refer to "LECSC2-T Operation Manual,chapter 6 and "LECSC2-T Operation Manual (Simplified Edition),section 5.3 for details. Refer to "LECSC2-T Operation Manual",chapter 6 for parameters which are not mentioned.
(2) 4[in](10.16[cm])100CFM(2.8m3/min) (3) SCCR(Short Circuit Current Rating) UL100kA (4) 15 [min] LECSC2-S5 LECSC2-S7 1 LECSC2-S8 LECSC1-S5 LECSC1-S7 2 A 12 (5) UL/C-UL (6) National Electrical Code , Canada Electrical Code LECSCLECSC40 A 13 1 111-17 1.1 12 1.1.1 CC-Link 12 1.1.2 13 1.1.3 14 1.2 16 1.3 18 1.4 1-10 1.5 1-12 1.6 1-13 1.6.1 1-13 1.7 1-14 1.8
LECSC2-S5 LECSC2-S7 LECSC2-S8 LECSC1-S5 LECSC1-S7 LECSC1-S8 Driver Power supply L1 L2 L3 Main circuit power supply 3-phase 200 to 230VAC, 50/60Hz L1L2L3 1-phase 200 to 230VAC, 50/60Hz L1L2 1-phase 100 to 120VAC, 50/60Hz L1 L2 When using driver built-in regenerative resistor, connect P( ) and D.
-S5 100 LECSC2-S7 200 LECSC2-S8 400 Model Compatible motor capacity [W] Absolute 18-bit encoder (Resolution: 262144 p/rev) Compatible encoder Single phase 100 to 120 VAC (50/60 Hz) Three phase 200 to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz) Power voltage [V] Main power supply Allowable voltage fluctuation [V] Rated current [A] Three phase 170 to 253 VAC, Single phase 170
LECSB1/LECSC1/LECSS1: Single phase 100 to 120 VAC, 50/60 Hz Connection terminal: L1,L2 LECSB2/LECSC2/LECSS2: Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2 L1 Main circuit L2 L2 power supply L3 L3 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2,L3 Do not connect. N N P1 P2 Connect between P1 and P2. (Connected at time of shipping.)