Speed entry settings require inputting target position, speed, acceleration, deceleration, and load mass., Electric Actuator, Card Motor, ELECTRIC ACTUATOR LAT3 LATC4, 70 lb

Speed entry settings require inputting target position, speed, acceleration, deceleration, and load mass., Electric Actuator, Card Motor, ELECTRIC ACTUATOR LAT3 LATC4, 70 lb

Speed entry settings require inputting target position, speed, acceleration, deceleration, and load mass., Electric Actuator, Card Motor, ELECTRIC ACTUATOR LAT3 LATC4, 989, 70 lb

Speed entry settings require inputting target position, speed, acceleration, deceleration, and load mass., Electric Actuator, Card Motor, ELECTRIC ACTUATOR LAT3 LATC4, 989, 70 lb

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: AN (LATCA, NPN), I/O Cable Length: 1m, Controller Mounting: D (DIN Rail Mounting, DIN Rail not Included)

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: AN (LATCA, NPN), I/O Cable Length: 5m, Controller Mounting: D (DIN Rail Mounting, DIN Rail not Included)

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: AP (LATCA, PNP), I/O Cable Length: 5m, Controller Mounting: D (DIN Rail Mounting, DIN Rail not Included)

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: AN (LATCA, NPN), I/O Cable Length: 5m

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: AP (LATCA, PNP), I/O Cable Length: 5m

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: NPN Controller, I/O Cable Length: 5m, Controller Mounting: DIN Rail Mounting, DIN Rail not Included

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: LATCA, NPN, I/O Cable Length: 1m, Controller Mounting: DIN Rail Mounting, DIN Rail not Included

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: LATCA, NPN, I/O Cable Length: 5m, Controller Mounting: DIN Rail Mounting, DIN Rail not Included

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: LATCA, PNP, I/O Cable Length: 5m, Controller Mounting: DIN Rail Mounting, DIN Rail not Included

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: LATCA, NPN, I/O Cable Length: 5m, Controller Mounting: -

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 5m, Controller: LATCA, PNP, I/O Cable Length: 5m, Controller Mounting: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CARD MOTOR, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, 1.54323 lb

Mechanical end stopper (Extended end) (Retracted end) Mechanical end stopper Model A H Jnote) Connector side LAT3-10 10 10.5 5 Opposite side of the connector LAT3-20 20 20.5 5 LAT3-30 30 30.5 15 LAT3-50 50 70 25 Table stop position when returning to the Origin position in the retracted direction. Table stop position when returning to the sensor origin.

Specifications LAT3-10 Stroke 10 mm, Resolution 30 m LAT3-20 Stroke 20 mm, Resolution 30 m Card Motor 8 options LAT3-30 Stroke 30 mm, Resolution 30 m (Refer to the table Product LAT3M-50 Stroke 50 mm, Resolution 5 m Number on the right) LAT3F-10 Stroke 10 mm, Resolution 1.25 m LAT3F-20 Stroke 20 mm, Resolution 1.25 m LAT3F-30 Stroke 30 mm, Resolution 1.25 m LAT3F-50 Stroke 50 mm, Resolution

(LAT3-10: 5.0, LAT3-20: 4.8, LAT3-30: 3.9, LAT3-50: 2.0) Note 4: Step Data No. 20 is used for Direct Operation. Note 5: If the target position exceeds the stroke range, the Card Motor operation speed is set to above 400 mm/s or any other impossible value is set, Step Data error will be generated from the Card Motor controller during the Step Data operation.

(LAT3-10: 5.0, LAT3-20: 4.8, LAT3-30: 3.9, LAT3-50: 2.0) Note 4: Step Data 20 is used in direct operation. Note 5: If the Target Position exceeds the stroke range, the Card Motor operation speed is over 400mm/s, or any other impossible value is set, during the operation Step Data error will occur. Please set values as appropriate.