SMC Corporation of America
Elite Part Number Search
Search Results "KK3P-04H"

Body size Applicable tubing O.D. mm Part no. 4 6 8 10 6 8 10 12 12 16 4 6 8 10 6 8 10 12 12 16 KK3P-04H -06H -08H -10H KK4P-06H -08H -10H -12H KK6P-12H -16H KK3S-04H -06H -08H -10H KK4S-06H -08H -10H -12H KK6S-12H -16H 1/8 1/8 1/4 1/4 1/2 1/2 Elbow type with One-touch fitting Elbow type with One-touch fitting Applicable tubing O.D. mm Applicable tubing O.D. mm Body size Part no.

Body size Applicable tubing O.D. mm Part no. 4 6 8 10 6 8 10 12 12 16 4 6 8 10 6 8 10 12 12 16 KK3P-04H -06H -08H -10H KK4P-06H -08H -10H -12H KK6P-12H -16H KK3S-04H -06H -08H -10H KK4S-06H -08H -10H -12H KK6S-12H -16H 1/8 1/8 1/4 1/4 1/2 1/2 Elbow type with One-touch fitting Elbow type with One-touch fitting Applicable tubing O.D. mm Applicable tubing O.D. mm Body size Part no.

Body size Applicable tubing O.D. mm Part no. 4 6 8 10 6 8 10 12 12 16 4 6 8 10 6 8 10 12 12 16 KK3P-04H -06H -08H -10H KK4P-06H -08H -10H -12H KK6P-12H -16H KK3S-04H -06H -08H -10H KK4S-06H -08H -10H -12H KK6S-12H -16H 1/8 1/8 1/4 1/4 1/2 1/2 Elbow type with One-touch fitting Elbow type with One-touch fitting Applicable tubing O.D. mm Applicable tubing O.D. mm Body size Part no.

Port size R 1/8 R 1/4 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 1/8 R 1/4 R 3/8 R 1/2 KK3P-01MS -02MS KK4P-01MS -02MS -03MS -04MS KKH3S-01MS -02MS KKH4S-01MS -02MS -03MS -04MS 1/8 1/8 1/4 1/4 Female thread type Female thread type Body size Port size Part no.

.+20mA, 3: 0..10V (default) , 4: 0..5V, 5: 1..5V, 6: 0..20mA, 7: 4..20mA 04h Channel 3 00h NumberOfEntries 4 01h Channel 0 0: None, 1: 2 value (default) , 2: 4 value, 3: 8 value .. .. .. 300Ch Slot0_AnalogFilter 04h Channel 3 0: None, 1: 2 value (default) , 2: 4 value, 3: 8 value 00h NumberOfEntries 4 01h Channel 0 0: false (default) .. .. .. 300Dh Slot0_FaultMode_Analog 04h Channel 3 0:

CONFIG Byte Description Command Response Phases in which the command can be executed Synchronization classification Asynchronous command 1 04H 04H Phase 2 and 3 2 ALARM Processing time Within 5 s Subcommand Cannot be used 3 Recalculates all currently set parameters and initializes position, etc.

CONFIG Byte Description Command Response 0 04H 04H The CONFIG command sets up devices.

PD23] for settings. _ x _ _ For manufacturer setting 0h x _ _ _ 0h PD25 *DO3 Output device selection 3 _ _ x x Device selection 04h Any output device can be assigned to the CN1-24 pin. Refer to table 5.11 in [Pr.

12 Get/Set Watchdog_timeout_action 13 Get Produced_connection_path_length 6 20h 04h 24h h 30h 03h 14 Get Produced_connection_path 11: EX250-SDN1 12: EX250-SDN1-X102 15 Get Consumed_connection_path_length 6 16 Get Consumed_connection_path 20h 04h 24h 25h 30h 03h 17 Get Production_inhibit_time 5-5.

Assembly Object (Class ID: 04h) 4-1. Class attribute ID Access rule Description Value 4-2. Class common service Service code Service name 4-3. Instance attribute ID Access rule Description 3 Get/Set Data 4-4. Solenoid Output Assembly Instance Instance Type Description Byte 35 Output 16 Solenoid Output Points 02h 37 Output 32 Solenoid Output Points 04h The data format is shown below.

Batch setting for all outputs: Fault setting Class Instance Description Value 66h 03h 0: Fault value 1: Output held Fault action 04h (Assembly) value 65h 03h 0: CLEAR 1: SET Fault : For details, refer to the DeviceNet Objects section.

, 24h, 05h, 30h, 03h: 14 Get Produced_connection_path EX12-SDN1/-X2 None: EX12-SDN1-X26/-X77 15 Get Consumed_connection_path_length 6 16 Get Consumed_connection_path 20h 04h 24h 23h 30h 03h 17 Get Production_inhibit_time 0 5-5.

COB-ID used by PDO Unsigned32 rw $NODEID+200h 2 VAR transmission type Unsigned8 rw FFh ro = read only access rw = read and write access const = read only access, value is constant -18No.EX-OMK0006-C Index Sub-Index Object Name Type Acc Default Receive PDO Mapping Parameter 1600 RECORD 1st receive PDO mapping PDO Mapping(21h) rw 0 VAR number of mapped application objects in PDO Unsigned8 rw 04h

Table 3.9-1 Function codes NO Code Name Function 1 04(04h) read input registers Reading multiple registers 2 06(06h) preset single register Writing registers *1 3 16(10h) preset multiple registers Writing multiple registers *1 Broadcast is not supported. 3.10 Checksum calculation method 3.10.1 LRC(ASCII) LRC checks the content of the message other than [:] of START and [CR] [LF] of END.

Table 3.9-1 Function codes NO Code Name Function 1 04(04h) read holding registers Reading multiple registers 2 06(06h) preset single register Writing registers1 3 16(10h) preset multiple registers Writing multiple registers 1 : Broadcast is not supported. 3.10 Checksum calculation method 3.10.1 LRC(ASCII) LRC checks the content of the message other than [:] of START and [CR][LF] of END.

No.1 No.2 No.3 Setting the Station Address Station Address S1 S2 No.1 03H 0 3 04H 0 4 No. 2 05H 0 5 No. 3 21 - 4. Parameter setting (Driver side) The setting is a necessary parameter. Please optionally set it. Please refer to "LECYU manual" for a detailed parameter.

Effective Area JIS Symbol Single plug Single socket Effective area mm2 Body size Plug Socket M5 KK2P-M5M KK2S-M5M 3.8 1/8 KK3P-01MS KK3S-01MS 20 Connected plug and socket 1/4 KK4P-02MS KK4S-02MS 39 1/2 KK6P-04MS KK6S-04MS 82 How to Order KK 4 S M S 02 Body size With sealant (male thread) 2 3 4 6 M5 1/8 1/4 1/2 Connection type Type Male thread Female thread With nut fitting Straight with One-touch

Flow characteristics 11,000 Series KK6 (KK6S-04MS+KK6P-04MS) 10,000 9,000 8,000 Flow rate (l/min(ANR)) 7,000 6,000 Series KK4 (KK4S-02MS+KK4P-02MS) 5,000 4,000 Series KK3 (KK3S-01MS+KK3P-01MS) Light weight The weight is minimized by adoption of stamped parts and resin parts as will as miniaturization of the body. 3,000 2,000 1,000 0 0.2 0 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.1 Pressure (MPa) PAT

Table 3.9-1 Function codes NO Code Name Function 1 04(04h) read holding registers Reading multiple registers 2 06(06h) preset single register Writing registers1 3 16(10h) preset multiple registers Writing multiple registers 1 : Broadcast is not supported. 3.10 Checksum calculation method 3.10.1 LRC(ASCII) LRC checks the content of the message other than [:] of START and [CR][LF] of END.