Manifold Controller, Gateway, ELECTRIC ACTUATOR CONTROLLER, N31, 250.00000 lb
Equivalent to 5U (EIA standards*1) 1 Refer to page 1 for details on 19-inch racks. 310 mm Fluid fill port Equivalent to 7U (EIA standards*1) Drain port 399 mm DI filter (Option) Equivalent to 9U (EIA standards*1) Particle filter (Standard) Bypass valve (Standard) 1.1/1.2/1.8/2.4/3.0/5.1 kW (60 Hz) Cooling capacity 0.1C Temperature stability Single-phase 100 VAC (50/60 Hz)/115 VAC (60 Hz)
JXD1 Manifold Controller. 350.00000 lb. N33.
JXD1 Manifold Controller. 350.00000 lb. N33.
The JXD1-M manifold controller can detect the actuator type, size and stroke when connected. The controller and cables are ordered separately, simplifying the part number.
The JXD1-M manifold controller can detect the actuator type, size and stroke when connected. The controller and cables are ordered separately, simplifying the part number.
The JXD1-M manifold controller can detect the actuator type, size and stroke when connected. The controller and cables are ordered separately, simplifying the part number.
The JXD1-M manifold controller can detect the actuator type, size and stroke when connected. The controller and cables are ordered separately, simplifying the part number.
JXD1 DIN rail mounting bracket, ELECTRIC ACTUATOR CONTROLLER, N31, 25.00000 lb
JXD1 Direct mounting bracket, ELECTRIC ACTUATOR CONTROLLER, N31, 20.00000 lb
JXD1-M TERMINATION UNIT, ELECTRIC ACTUATOR CONTROLLER, N31, 100.00000 lb
JXD1-M PWR SUPPLY PLUG, ELECTRIC ACTUATOR CONTROLLER, N31, 20.00000 lb
JXD1-M PWR SUPPLY BLOCK PLUG, ELECTRIC ACTUATOR CONTROLLER, N31, 25.00000 lb
JXD1-M MTR PWR SUPPLY PLUG, ELECTRIC ACTUATOR CONTROLLER, N31, 15.00000 lb
JXD1-M CC LINK COMM PLUG, ELECTRIC ACTUATOR CONTROLLER, N31, 10.00000 lb
The JXD1-MDP driver connects LE2 actuators to the manifold controller system. The drivers reside between a gateway and termination unit to complete the system. Each driver can host one or two actuator axes. Up to 8 drivers can be connected in a manifold, controlling up to 16 axes. Operation and feedback signals between the PLC and actuator motor are carried across this connection.
The JXD1-MTR termination unit closes the manifold controller system after assembling 1 or more drivers to the gateway. Only one connection is made by mating this unit to the last driver in the manifold. The right direct or DIN rail mounting bracket assembles to the rear. It is optional to order this unit separately, but it can also be included within the gateway unit part number.
EN 60079-0: 2012 EN 60079-11: 2012 EN 60079-26: 2007 EN 60079-31: 2009 EN 60079-0: 2012 EN 60079-11: 2012 EN 60079-15: 2010 EN 60079-31: 2009 II 3 G Ex nA IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Input: Ui 30 V, Ii 152 mA Output: Ui 30 V, Ii 152 mA II 3 G Ex ic IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Input: Ui 30 V, Ii 152 mA, Pmax = device limits itself, Ci 22 nF, Li 53 H.
(PFH) PFH = 6.4 10-9 [1/h] Number of on/off times of STO 1,000,000 times LVD: EN 61800-5-1 CE marking EMC: EN 61800-3 MD: EN ISO 13849-1, EN 61800-5-2, EN 62061 Note 1.