with M5 thread Flow direction: Right to left With element service indicator Size 1/8 1/4 3/8 1/2 3/4 1 1 1/2 2 01 02 03 04 06 10 14 20 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B, 650 75B, 850 Rc NPT G 1/8 1/4 3/8 1/2 3/4 1 1 1/2 Nil J M R T Nil B C D Option Accessory Size Bore size RT T R JR JRT MR J MRT JT MT M 03 06 04 01 02 20 14 Size 10 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B
PC79 *COP10 Function selection C10 _ _ _ x _ _ _ x (BIN): For manufacturer setting 0h (HEX) _ _ x _ (BIN): DI1 status reading selection Select DI1 (bit 17) status reading. 0: The on/off status of the input device is returned. 1: The on/off status of the CN3-2 pin is returned. _ x _ _ (BIN): DI2 status reading selection Select DI2 (bit 18) status reading. 0: The on/off status of the input
Industrial Filters 453 Series ARM10/11A/11B Replacement Procedure of Diaphragm 2 2.
(L4) (L3) (5.25) L2 L1 Made by CONINVERS GmbH HC-26P1NRAWF00 34.5 6.5 59 Indicator light Manual override 4 x M5 mounting hole 73.5 <77.5> 1 0.9 29.5 (35) (5.5) 120 <126.9> 22 10.6 80 4 46.2 (12) 13 73.7 U side D side n 8 7 Stations 6 5 4 3 2 1 C10 [3(R) EXH port] C10: 10 one-touch fitting C10 [1(P) SUP port] C10: 10 one-touch fitting R EXH R EXH DIN rail clamp screw B B B B B B B B P X P
(L4) (L3) (5.25) L2 L1 Made by CONINVERS GmbH HC-26P1NRAWF00 34.5 6.5 59 Indicator light Manual override 4 x M5 mounting hole 73.5 <77.5> 1 0.9 29.5 (35) (5.5) 120 <126.9> 22 10.6 80 4 46.2 (12) 13 73.7 U side D side n 8 7 Stations 6 5 4 3 2 1 C10 [3(R) EXH port] C10: 10 One-touch fitting C10 [1(P) SUP port] C10: 10 One-touch fitting R EXH R EXH DIN rail clamp screw B B B B B B B B P X P
(L4) (L3) (5.25) L2 L1 Made by CONINVERS GmbH HC-26P1NRAWF00 34.5 6.5 59 Indicator light Manual override 4 x M5 mounting hole 73.5 <77.5> 1 0.9 29.5 (35) (5.5) 120 <126.9> 22 10.6 80 4 46.2 (12) 13 73.7 U side D side n 8 7 Stations 6 5 4 3 2 1 C10 [3(R) EXH port] C10: 10 One-touch fitting C10 [1(P) SUP port] C10: 10 One-touch fitting R EXH R EXH DIN rail clamp screw B B B B B B B B P X P
(L4) (L3) (5.25) L2 L1 Made by CONINVERS GmbH HC-26P1NRAWF00 34.5 6.5 59 Indicator light Manual override 4 x M5 mounting hole 73.5 <77.5> 1 0.9 29.5 (35) (5.5) 120 <126.9> 22 10.6 80 4 46.2 (12) 13 73.7 U side D side n 8 7 Stations 6 5 4 3 2 1 C10 [3(R) EXH port] C10: 10 One-touch fitting C10 [1(P) SUP port] C10: 10 One-touch fitting R EXH R EXH DIN rail clamp screw B B B B B B B B P X P
DI unit 4 ~ = D side U side Stations 1 2 3 4 5 6 7 8 n 23 75.5 61.5 1.6 8 73.7 49 24.5 13.2 9.5 16 R (EXH) port C10 C4: 4 One-touch fitting 2n-C4, C6, C8 P (SUP) port C10 C8: 8 One-touch fitting C6: 6 One-touch fitting Formula L1 = 16n + 36.5, L2 = 16n + 186 (In the case of 1 pc.
(Series VQ2000) Porting specifications Applicable stations Port size Port location A, B P, R Series Side Side Max. 24 Max. 20 C3, C4, C6, M5 C4, C6, C8 C8 C10 VQ1000 VQ2000 Terminal Block Connection Open the terminal block cover for wire connection. Sequence 1.
C10: 10 (SMC) N11: 3/8" (SMC) (C12: 12 (SMC) (In case of double sided type)) [Communication connector D-sub] (DIN rail clamping screw) R R R BUS OUT BUS 76.7 76.5 12 3 12 3 3 72 BUS IN X 49.5 B B B B B B B B P X P X P 12 PWR PWR 30 25 A 1 1 A 1 A A A A A A A 55 25 13 (7.5) 18 55 One-touch fitting [4(A), 2(B) port] Applicable tube O.D.
Series: 5 (JSY5000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C10 (ø10 One-touch Fitting)
Series: 5 (JSY5000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C10 (ø10 One-touch Fitting)
Series: JSY5000, Type: Side-Ported, Serial Interface, EX260, SI Unit: EtherNet/IPâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 8 Stations, P,E Port Location: Both Sides, 2 to 24 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø10 One-touch Fitting, Mounting: -, DIN Rail Option: -
Series: JSY5000, Type: Side-Ported, Serial Interface, EX260, SI Unit: EtherNet/IPâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 8 Stations, P,E Port Location: Both Sides, 2 to 24 Stations, SUP/EXH Block: Internal Pilot, Built-in Silencer, A,B Port Size: ø10 One-touch Fitting, Mounting: -, DIN Rail Option: -
Event EventQualifier Event Content Status Code Value MODE TYPE SOURCE INSTANCE bit 6-7 bit 4-5 bit 3 bit 0-2 Device hardware failure Occur 0xF4 11b(3)(appears) 0x5000 Release 0xB4 10b(2)(disappears) Occur 0xF4 11b(3)(appears) 0x5011 Release 0xB4 10b(2)(disappears) Non volatile memory failure Valve short circuit Occur 0xF4 11b(3)(appears) 0x1800 Release 0xB4 10b(2)(disappears) Occur 0xF4 11b
Example: absolute position data: -10 (F6H) 10b Appendix 01b 10 Decimal 11b 11b F FFF6 Hexadecimal 11b 11b 1 1 1 0110 Binary 11b 11b When the binary data of each 2 bits of the absolute position data is added up, "10 1101 b" is obtained. 11b 11b 11b 11b 11b 11b 11b 11b + 101101b Therefore, the checksum of "-10" (absolute position data) is "2DH" 12 12 12.
Example: ABS data: 10 (F6H) 10b
391 80 540.5 80 11B 450 550 650 850 22B 37B 75B 1 2 1 2 14-20-55 Water Separator, Oil Mist Separator, Deodorizer Made to Order Specifications: Please consult with SMC for detailed specifications, size and delivery. 3.
Industrial Filters 453 Series ARM10/11A/11B Replacement Procedure of Diaphragm 2 2.
Industrial Filters 453 Series ARM10/11A/11B Replacement Procedure of Diaphragm 2 2.