SMC Corporation of America
Elite Part Number Search
Search Results "JJ5SY3-10SNA-04B-C6"

C6: 6 (SMC) N7: 1/4" (SMC) One-touch fitting [PE: Pilot EXH port] Applicable tube O.D. C6: 6 (SMC) N7: 1/4" (SMC) Applicable tube O.D.

C6: 6 (SMC) N7: 1/4" (SMC) One-touch fitting [PE: Pilot EXH port] Applicable tube O.D. C6: 6 (SMC) N7: 1/4" (SMC) Applicable tube O.D.

Ejector valve ZYY35LZ-10S-E15C Double solenoid (24 VDC) SY3240-5LZ J ZZY 1 U Single solenoid (24 VDC) SY3140-5LZ Blanking plate assembly SX3000-75-1A Cylinder port size C6 : With 6 One-touch fitting Manifold base (4 stations) ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Example) ZYY-J3U ZYY35LZ-10S1-E15C ZYY35LZ-10S 2 SET 1 SET 1 SET U side Stations3 2 1 D side 13-8-6 7 Ejector

manual drain Regulator Air release valve Pressure switch Blank plate (air release valve) Blank plate (filter, regulator) Number of manifold blocks required for mounting (stations) 2 2 2 2 2 2 2 1 Manifold Specifications Piping specifications Ports 2 (B), 4 (A) Applicable solenoid valve Manifold block size Weight kg Stations 1 (P), 3 (R2) 5 (R1) port size Piping direction Size Rc1/4 Rc3/8 C6

C8 (A, B port) D side Bottom ported: VV5FR2-01TStation 2Port size C6, C8 Light/Surge voltage suppressor (At FZ) 2-Rc 1/8 (PE port) 2-G 3/4 (Electrical entry) C6: Max. 6 C8: Max. 6.5 6-Rc 1/4 (P, EA, EB port) With terminal block (One-piece junction cover): VV5FR2-01T1Station 1Port size U side 5n-Rc 1/8 (Pitch) P = 28 Stations 2n-Rc 1/8, 1/4 C6, C8 (A, B port) D side Bottom ported: VV5FR2-

Blanking plate (Filter, Regulator) Blanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) 2 2 2 2 2 2 2 1 Manifold Specifications Porting specifications Manifold block size Applicable solenoid valve Weight (kg) Stations 1(P), 3(R2) 5(R1) port size 2(B), 4(A) port Port location Port size 1/4 3/8 C6 (6) C8 (8) C10 (10) Right, Left Note) 1/4 3/8 C12 (12)

Blanking plate (Filter, Regulator) Blanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) 2 2 2 2 2 2 2 1 Manifold Specifications Porting specifications Manifold block size Applicable solenoid valve Weight (kg) Stations 1(P), 3(R2) 5(R1) port size 2(B), 4(A) port Port location Port size 1/4 3/8 C6 (6) C8 (8) C10 (10) Right, Left Note) 1/4 3/8 C12 (12)

Order (Manifold) 5 03R 04D Q VV72 E Stations Air release valve Piping/P, R1, R2 Port Air release valve/Voltage Piping/A, B port Silencer box (Bottom) 1 2 (Top) 1 2 (Both sides) 1 2 (Bottom) 3 4 (Top) 3 4 (Both sides) 3 4 (Right) 3 8 (Right) 1 2 (Left) 3 8 (Left) 1 2 (Bottom) 3 8 (Bottom) 1 2 Combination Without air release valve 1 1 Without air release valve With air release valve 04D 04U 04B

Series: 3 (JSY3000), Type: 10 (Side-Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable), Connector Entry Direction: 1 (Upward), Valve Stations: 4 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10 (Side-Ported), Connector Type: FW (D-sub Connector, IP67, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 4 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10 (Side-Ported), Connector Type: FW (D-sub Connector, IP67, 25 Pins), Connector Entry Direction: 2 (Lateral), Valve Stations: 4 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: ZE (EtherNet/IPâ„¢, Negative Common), Input Block Stations: 5 Stations, Input Block Type: A (PNP Sensor Input, M12, 2 Inputs), Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 4 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 4 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: FA (PROFINET - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 4 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 41 (Bottom Ported), Valve Stations: 4 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: C6 (ø6 One-touch Fitting; Fixed)

Series: JSY3000, Type: Side-Ported, Serial Interface, EX250, SI Unit: w/o SI Unit, Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: Internal Pilot, Both Sides, 2 to 24 Stations, A,B Port Size: ø6 One-touch Fitting, Mounting: -, DIN Rail Option: -

Series: JSY3000, Type: Side-Ported, Serial Interface, EX250, SI Unit: EtherNet/IPâ„¢, Negative Common, Input Block Stations: 5 Stations, Input Block Type: PNP Sensor Input, M12, 2 Inputs, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: Internal Pilot, Both Sides, 2 to 24 Stations, A,B Port Size: ø6 One-touch Fitting, Mounting: -, DIN Rail Option: -

Series: JSY3000, Type: Side-Ported, Connector Type: D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable, Connector Entry Direction: Upward, Valve Stations: 4 Stations, P,E Port Location: Both Sides, 2 to 24 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø6 One-touch Fitting, Mounting: -, DIN Rail Option: -