Series: JSY1000, Type: Bottom Ported, Valve Stations: 9 Stations, P,E Port Entry: U Side, A,B Port Size: M3 x 0.5, Thread Size: -, Mounting: -, DIN Rail Option: -
Series: JSY1000, Type: Bottom Ported, Valve Stations: 12 Stations, P,E Port Entry: Both Sides, A,B Port Size: ø4 One-touch Fitting; Fixed, Thread Size: G, Mounting: -, DIN Rail Option: -
Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable), Connector Entry Direction: 1 (Upward), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable), Connector Entry Direction: 1 (Upward), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: P (Flat Ribbon Cable, IP40, 26 Pins, Entry Direction Adjustable), Connector Entry Direction: 1 (Upward), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 1 (JSY1000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: FA (PROFINET - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: 0 (DIN Rail Mounting
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 8 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: C4 (ø4 One-touch Fitting; Fixed)
Series: JSY1000, Type: Side-Ported, Serial Interface, EX250, SI Unit: w/o SI Unit, Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: Internal Pilot, Both Sides, 2 to 24 Stations, A,B Port Size: ø4 One-touch Fitting, Mounting: -, DIN Rail Option: -
Series: JSY1000, Type: Side-Ported, Connector Type: D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable, Connector Entry Direction: Upward, Valve Stations: 8 Stations, P,E Port Location: Both Sides, 2 to 24 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø4 One-touch Fitting, Mounting: -, DIN Rail Option: -
Series: JSY1000, Type: Side-Ported, Connector Type: D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable, Connector Entry Direction: Upward, Valve Stations: 8 Stations, P,E Port Location: Both Sides, 2 to 24 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø6 One-touch Fitting, Mounting: -, DIN Rail Option: -
Series: JSY1000, Type: Side-Ported, Connector Type: Flat Ribbon Cable, IP40, 26 Pins, Entry Direction Adjustable, Connector Entry Direction: Upward, Valve Stations: 8 Stations, P,E Port Location: Both Sides, 2 to 24 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø6 One-touch Fitting, Mounting: -, DIN Rail Option: -