Flow Sensor Series PFMV5 How to Order PFMV5 05 1 Option (shipped together) Measurement flow range 0.0 to 0.5 l/min 05 10 30 05F 10F 30F None With L-type bracket Nil 0.0 to 1.0 l/min 0.0 to 3.0 l/min 0.5 to 0.5 l/min 1.0 to 1.0 l/min 3.0 to 3.0 l/min A Mounting screw Analog output (1 to 5 V) Output specification 1 2 L-type brackets (with 2 mounting screws) are included.
P1 P2 P1 P2 Vacuum source (Vacuum pump) Nozzle Nozzle Note) Since the calculated value may not meet the approximate value due to leakage and pressure loss in the piping system, please check the result by using actual equipment. 950 Flow Sensor Series PFMV5 How to Order PFMV5 05 1 Option (shipped together) Measurement flow range 05 10 30 05F 10F 30F Nil 0.0 to 0.5 l/min None With L-type bracket
Series: JSY1000, Type: Side-Ported, Serial Interface, EX600, SI Unit: EA [EtherNet/IPâ„¢ (2 Ports)], SI Unit Common, End Plate: Power Supply w/M12 Connector, NPN, I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: Internal Pilot, Built-in Silencer; Both Sides, 2 to 24 Stations, A,B Port Size: ø6 One-touch Fitting, Mounting: DIN Rail Mounting, DIN Rail Option:
Model: Side-Ported, Serial Interface, SI Unit Specification: EtherNet/IPâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: PNP, Valve Stations: 06 Stations, P, E Port Location: D Side, SUP/EXH Block: Internal Pilot, Built-in Silencer, A, B Port Size: ø4 One-touch Fitting, Mounting: DIN Rail Mounting w/o Name Plate, w/o Station Number, DIN Rail Option: 7
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 06 Stations, P, E Port Location: D (D Side), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w/
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: 2 Stations, Input Block Type, Common Spec: C (Positive Common, M8, 4 Inputs), Valve Stations: 8 Stations, P,E Port Location, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: D (DIN
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: 2 Stations, Input Block Type, Common Spec: C (Positive Common, M8, 4 Inputs), Valve Stations: 4 Stations, P,E Port Location, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)
Model: 10S (Side Ported), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: 2 Stations, Input Block Type, Common Spec: C (Positive Common, M8, 4 Inputs), Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: N3 (ø5/32" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 9 (Longer
Model: 10S (Side Ported), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: 2 Stations, Input Block Type, Common Spec: C (Positive Common, M8, 4 Inputs), Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 9 (Longer than
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
Model: Side-Ported, Serial Interface, SI Unit Specification: DeviceNetâ„¢, Input Block Stations: 2 Stations, Input Block Type, Common Spec: Positive Common, M8, 4 Inputs, Valve Stations: 8 Stations, P,E Port Location, SUP/EXH Assembly: Port Location Both Sides, Internal Pilot, A, B Port Size: ø1/4" One-touch Fitting, Mounting: DIN Rail Mounting w/o Name Plate, DIN Rail Option: -
Model: Side-Ported, Serial Interface, SI Unit Specification: DeviceNetâ„¢, Input Block Stations: 2 Stations, Input Block Type, Common Spec: Positive Common, M8, 4 Inputs, Valve Stations: 4 Stations, P,E Port Location, SUP/EXH Assembly: Port Location Both Sides, Internal Pilot, Built-in Silencer, A, B Port Size: ø6 One-touch Fitting, Mounting: -, DIN Rail Option: -
Model: Side Ported, SI Unit Specification: DeviceNetâ„¢, Input Block Stations: 2 Stations, Input Block Type, Common Spec: Positive Common, M8, 4 Inputs, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: Port Location Both Sides, Internal Pilot, A, B Port Size: ø5/32" One-touch Fitting, Mounting: DIN Rail Mounting w/o Name Plate, DIN Rail Option: Longer than Standard DIN Rail
Model: Side Ported, SI Unit Specification: DeviceNetâ„¢, Input Block Stations: 2 Stations, Input Block Type, Common Spec: Positive Common, M8, 4 Inputs, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: Port Location Both Sides, Internal Pilot, A, B Port Size: ø1/4" One-touch Fitting, Mounting: DIN Rail Mounting w/o Name Plate, DIN Rail Option: Longer than Standard DIN Rail
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: WE (EtherNet/IPâ„¢, Compatible Wirless Base Unit), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Model: 11S6 (Bottom Ported), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: N7 (ø1/4" One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: N7 (ø1/4" One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: N9 (ø5/16" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 0 (w/o DIN Rail with Bracket)