Magnet: Built-in Magnet, Mounting: Through-hole (Standard), Bore Size: 12mm, Port Thread: M thread: ø12 to ø32, Rc: ø50 to ø100, Stroke: 30mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in Magnet), Mounting: Through-hole (Standard), Bore Size: 12mm, Port Thread: M thread: ø12 to ø32, Rc: ø50 to ø100, Stroke: 15mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting: Through-hole (Standard), Bore Size: 12mm, Port Thread: M thread: ø12 to ø32, Rc: ø50 to ø100, Stroke: 15mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)

Magnet: Built-in Magnet, Mounting: Through-hole (Standard), Bore Size: 12mm, Port Thread: M thread: ø12 to ø32, Rc: ø50 to ø100, Stroke: 15mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, Mounting: Through-hole (Standard), Bore Size: 12mm, Port Thread: M thread: ø12 to ø32, Rc: ø50 to ø100, Stroke: 15mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M8-3 Pin Connector, Number: -

2 (n = 2, 4, 6) Note 3) 50 + 27.5 (n 2) (n = 2, 3, 4, 5) CQ2 CQS Luberetainer D-M9lV 5 5 10 + 10 (n 2) (n = 4, 6) Note 4) D-A9lV 5 10 10 + 15 (n 2) (n = 4, 6) Note 4) JA D-M9l D-A9l 10 (5) Note 5) 10 15 + 15 (n 2) (n = 4, 6) Note 4) MXH D-M9lWV D-M9lAV 10 15 15 + 15 (n 2) (n = 4, 6) Note 4) MXQ D-M9lW 15 (10) Note 5) 15 20 + 15 (n 2) (n = 4, 6) Note 4) MGP D-M9lA 15 (10) Note

25 30 30 Gripping point L (mm) Gripping point L (mm) 15 15 F MRHQ F Misc.

2) (n = 4, 6)4 MB D-A9V 5 10 10 + 15 (n 2) (n = 4, 6)4 MB1 D-M9 D-A9 10 (5)5 10 15 + 15 (n 2) (n = 4, 6)4 CA2 D-M9WV D-M9AV 10 15 15 + 15 (n 2) (n = 4, 6)4 D-M9W 15 (10)5 15 20 + 15 (n 2) (n = 4, 6)4 CS1 D-M9A 15 (10)5 20 (15)5 20 + 15 (n 2) (n = 4, 6)4 CS2 D-F7 D-J79 5 5 15 + 15 (n 2) (n = 4, 6)4 Rail mounting D-F7V D-J79C 5 5 10 + 10 (n 2) (n = 4, 6)4 D-F7W/J79W D-F7BA

(n 2) (n = 4, 6) D-M9l D-A9l*2 10 10 15 + 15 (n 2) (n = 4, 6) D-F7lWV D-F7BAV D-A79W*2 10 15 10 + 15 (n 2) (n = 4, 6) Rail mounting D-F7lW D-J79W D-F7BA 10 15 15 + 20 (n 2) (n = 4, 6) D-M9lWV D-M9lAV 10 15 15 + 15 (n 2) (n = 4, 6) D-F7lW D-J79W D-F7BA 10 15 15 + 20 (n 2) (n = 4, 6) D-M9lW 15 15 15 + 15 (n 2) (n = 4, 6) D-M9lA 15 20 20 + 15 (n 2) (n = 4, 6) *1 Auto switch

6 Special resin MYA63-15-R6659 MYA40-15-R6658 MYA25-15-R6657 MYA16-15-R6656 Scraper !

15 20 15 With 2 pcs. 5 10 10 15 15 20 20 15 The applicable auto switches for the CDQ2 R/ V (water resistant) are the D-M9 A(V)L type.

15 20 15 10 With 2 pcs. 5 10 15 15 20 20 15 The applicable auto switches for the CDQ2lR/lV (water resistant) are the D-M9lA(V)L type.

Same side Same side Different sides Different sides D-C7/C80 50 50 + 45 (n 2) 10 15 15 + 45 ( n 2) (n = 2, 4, 6) 2 D-H7/H7W D-H7NF 60 + 45 (n 2) 60 15 10 15 + 50 ( n 2) (n = 2, 4, 6) Mounting D-C73C/C80C D-H7C D-B5 D-B64 D-G5NTL 2 65 + 50 (n 2) 65 15 10 Warning 15 + 50 ( n 2) (n = 2, 4, 6) 15 75 2 10 1. Do not rotate the cover.

(10) 15 (5) 1 pc. 10 15 5 10 10 15 (10) 15 (5) 2 pcs. 10 15 5 Note 1) 25 is only applicable for D-P3DW.

4.5 9.5 5, 10 15 5, 10 15 5, 10 15 5, 10 15 5, 10 15 10 16.5 16.5 12.5 16 20 20 16 20 24 24 20 25 26.5 26.5 22.5 23.5 32 27.5 27.5 Note 1) Figures in the table above are used as a reference when mounting the auto switches for stroke end detection.

35 30 0.5 MPa 0.5 MPa Gripping force (N) MHF Gripping force (N) 30 25 25 20 20 15 15 F 0.4 MPa 0.4 MPa MHL 0.3 MPa 0.3 MPa MHR 0.2 MPa 0.2 MPa 10 10 5 5 MHK F F 0 0 5 5 25 25 10 10 15 15 20 20 30 30 35 35 Gripping point L (mm) Gripping point L (mm) MHS MHC MHS3-25D MHS3-25D Internal grip 70 MHT 60 60 Pressure 0.6 MPa Pressure 0.6 MPa 50 50 MHY Gripping force (N) Gripping force (N) 0.5 MPa

12.5 17.5 2.5 -2.5 2 -3 0 -5 -1.5 -6.5 -2.5 -7.5 7.5 12.5 8 13 10 15 11 16 12.5 17.5 3.5 8.5 4 9 6 11 7 12 8.5 13.5 0.5 -4.5 0 -5 -2 -7 -3.5 -8.5 -4.5 -9.5 5, 10 15 5, 10 15 5, 10 15 5, 10 15 5, 10 15 10 12.5 16.5 16.5 16 16 20 20 20 20 24 24 25 22.5 26.5 26.5 32 23.5 27.5 27.5 Note 1) Figures in the table above are used as a reference when mounting the auto switches for stroke end detection

10 15 50 15 + 45 (n 2) 2 (n = 2, 4, 6)Note 3) 50 + 45 (n 2) (n = 2, 3, 4, 5) D-H7l D-H7lW D-H7BA D-H7NF 10 15 60 15 + 45 (n 2) 2 (n = 2, 4, 6)Note 3) 60 + 45 (n 2) (n = 2, 3, 4, 5) CG3 JMB MB D-H7C D-C73C D-C80C 10 15 65 15 + 50 (n 2) 2 (n = 2, 4, 6)Note 3) 65 + 50 (n 2) (n = 2, 3, 4, 5) D-G5NT D-B5l/B64 10 15 75 15 + 50 (n 2) 2 (n = 2, 4, 6)Note 3) 75 + 55 (n 2) (n = 2, 3, 4, 5)

For dimensions of 25 stroke, refer to page 8-26-20. 12.5 15 15 10.5 12.5 15 15 10 23 23 12.5 15 12.5 15 15 17.5 15 17.5 15 17.5 15 17.5 9 17.5 14 16 22 23 23 24 22 23 23 24 Note 2) For 25 stroke, the shock absorber is mounted on a single side of the plate.

(10) 15 (5) 15 With 2 pcs. 5 10 10 10 15 (10) 15 (5) 15 REC Note 1) 25 is only applicable for the D-P3DWAl.