This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Mounting: Foot Style, Applicable Bore Size: -, Nominal Thread: M12 X 1.5, Bore Size: 40mm
14 14 14 14 14 14 D side U side For the I/O Unit part number mounted, refer to the following pages.
P R V Nil 1 2 3 Size Size Air compressor size Note) 100 100 kW 125 125 kW 150 150 kW Note) Note that the above values are for reference only.
8 50 130 50 2 58 9 9 58 150 63 2 70 11 9 58 150 80 3 82 11 11 71 182 100 3 100 14 14 71 182 Courtesy of Steven Engineering, Inc. !
63 2 70 11 9 58 150 80 3 82 11 11 71 182 100 3 100 14 14 71 182 Courtesy of Steven Engineering, Inc. !
150 st 150 st or less Over 150 st 150 st or less Over 150 st 150 st or less Over 150 st 80 80 80 45.5 40.5 24 38.5 0 146.5 193 30 46.5 25 160 193 13.5 46.5 100 100 100 49 43.5 26.5 41 166 203 36 0 37 30 180 203 14 37 8-19-48 Compact Guide Cylinder Heavy Duty Guide Rod Type Series MGPS 50, 80 How to Order MX MGP 50 50 S Y7BW MTS MY CY Number of auto switches 2 pcs. 1 pc.
28 12 13 13 13 54 1/8 83 45.5 40 Up to 500 14 12 27 35 10 30 22 8 52 104 38 10 14 28 16 13 14 16.5 63 1/8 91 52.5 50 Up to 600 18 15 32 40 12.5 35 27 11 65 120.5 46.5 14 20 40 20 14 15.5 19 75 1/4 104.5 58.5 63 Up to 600 18 12 32 45 17.5 35 27 11 75 134.5 56.5 14 20 40 20 14 16.5 23 90 1/4 119.5 68 80 Up to 800 22 18 37 45 22 40 32 13 95 169 72 22 30 60 25 20 19 33 102 1/4 150 81 100 Up
, 175, 200, 250, 300 131 90 27 16 45 49.5 64 M14 x 1.5 14 4.5 14 100, 125, 150, 175, 200, 250, 300, 400, 500 177 136 27 16 52 57 71.5 M14 x 1.5 24 5 14 200, 300, 500 193 144 32 20 64 71 85.5 M18 x 1.5 25.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 x 1.5 21 7 18 T P L M N O Q X Z Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc 1/8 56 57.5 30 14 41 40 5.5 M6 x 1 Rc 1/8 62 64.5 30 14 49
166 150 134 118 102 326 L4 15 17 12.5 14 16 17.5 13 15 16.5 12 14 15.5 17.5 13 13.5 269 Series SY3000/5000 45S6A Type Manifold Option Blanking plate assembly For type SS5Y 3 5-45S6A Model Blanking plate assembly part no.
I-020B I-032B I-040B +0.058 0 0.1 0.2 +0.058 0 0.1 0.2 9 9 9 9 18 41 M8 x 1.25 14 10 11 66 46 16 20 36 M8 x 1.25 10 14 +0.058 0 0.1 0.2 +0.058 0 0.1 0.2 9 9 9 9 22 45 14 10 14 69 48 18 20 38 10 14 M10 x 1.25 M10 x 1.25 +0.070 0 0.1 0.3 +0.070 0 0.1 0.3 12 16 12 16 24 50 20 14 13 92 69 22 24 55 20 M14 x 1.5 M14 x 1.5 15.5 Double Knuckle Joint (mm) Y (Max.)
. 14-9 14.3.4 Checksum . 14-9 14.3.5 Time-out processing . 14-9 14.3.6 Retry processing . 14-10 14.3.7 Initialization . 14-10 14.3.8 Communication procedure example . 14-11 14.4 Command and data No. list . 14-12 14.4.1 Reading command . 14-12 14.4.2 Writing commands . 14-18 14.5 Detailed explanations of commands . 14-20 14.5.1 Data processing . 14-20 14.5.2 Status display mode . 14-21 14.5.3
[mm] Bore size Stroke range A B CD CT CU CW CX CY CZ D E J K L M XC26A XC26B XC26C 32 125, 150, 175, 200, 250, 300 143.5 45.5 10 5 14 20 12.5 52.5 36 16 45 4.5 14 56 34 40 155 55 10 6 14 22 16.5 19.5 12.5 52.5 36 16 52 5 14 56 40 50 182.5 55.5 14 7 20 28 16.5 19.5 12.5 66 44 20 64 7 17 69 50 63 186 57 14 8 20 30 16.5 19.5 12.5 66 44 20 77 7 17 69 60 Bore size O P Q R RR RR1 Th9 U1 W Z A1
AT11C-06 AFF8B-04 IDF8DAM350-04 AMD350-04 11 1.5 HAA15-10 HAW22-14 AT11C-06 AFF8B-06 IDF11CAM350-06 AMD450-06 15 2.0 HAA22-14 HAW22-14 AT22C-14 AFF11B-06 IDF15CAM450-06 AMD450-06 22 3.0 HAA37-14 HAW37-14 AT22C-14 AFF22B-10 IDF22C1-3 AM550-10 AMD550-10 27 3.5 HAA37-14 HAW37-14 AT37C-14 AFF22B-10 IDF22C1-3 AM550-10 AMD550-10 37 5.0 HAW55-20 AT37C-14 AFF37B-14 IDF37C1-3 AM650-14 AMD650-14
If the voltage drop (maximum of 5.2 V) interferes with the relay operation, apply high voltage (maximum of 26.4 V) from external source. 13 13 14. APPLICATION OF FUNCTIONS 14. APPLICATION OF FUNCTIONS .2 14.1 Infinite feed function (setting degree) .2 14 1 14. APPLICATION OF FUNCTIONS 14.
Overall manifold length Overall manifold length Approx. 29% reduction SY5000 manifold SY5000: 3 stations SY3000 manifold SY3000: 4 stations Mixed manifold SY5000: 3 stations, SY3000: 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 B 12 B 12 B 12 B 12 B
[mm] Bore size A B C D F FB FC FT FX FY FZ GB H MM NA NB NC NN S 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st 61 to 75 st 76 to 100 st 101 to 125 st 126 to 150 st 6 15 12 14 3 8 11 4.5 1.6 24 14 32 5 28 M3 x 0.5 3 9.5 7 M6 x 1.0 37 (42) 46 (51) 50 (55) 64 (69) 10 15 12 14 4 8 13 4.5 1.6 24 14 32 5 28 M4 x 0.7 4.8 9.5 M8 x 1.0 45.5 53 65 77 16 15 18.3 20 5 8 19 5.5 2.3 33 20 42 5 28 M5
Solid State Auto Switch: D-M9m/M9mW [mm] Model A stroke E stroke 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6(A) 18 7.4 7.4 7.4 7.4 0 0.6 3.6 5.6 5.6 MXQ8(A, C) 13.9 13.9 13.9 13.9 13.9 13.9 5.1 5.1 5.1 11.1 28.1 5.1 MXQ12(A, C) 26.5 16.5 16.5 16.5 16.5 16.5 16.5 4.1 6.1 6.1 14.1 14.1 33.1 33.1 MXQ16(A) 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20 14 14 21 21 27 46
27 11 9 58 5.5 10 M10 x 1.5 38 7 34.5 17 M8 x 1 12+0.08 0 33.1 38 47 40 21 24 M38 x 1.5 14 46.5 38 G1/4 35 16 32 13 12 69 7 12 M12 x 1.75 50 8 42.5 19 M10 x 1 14+0.08 0 39.5 45 57 Double End Boss-cut [mm] Item Stroke Bore size S (XC) ZZ 1 to 50 51 to 100 101 to 150 151 to 200 201 to 250 1 to 50 51 to 100 101 to 150 151 to 200 201 to 250 1 to 50 51 to 100 101 to 150 151 to 200 201 to 250