Model: 1.8 m³/min, Input/Output: NPN, Input/Output, Power Supply Cable, AC Adapter: w/Power Supply Cable, 3m, Bracket: w/Bracket, Automatic Cleaning Unit, Louver: w/Adjustable Louver, Filter: w/Filter
And for the IZF21/31, the excess current on output circuit, incorrect high voltage, power supply failure, fan motor failure, CPU failure, maintenance warning, emitter cartridge mounting failure, and automatic cleaning failure alarms cannot be checked.
However, for IZF21/31 series ionizers, the power cable connector cannot be ordered individually.
Instead, replace the power cable as a whole with the part number “IZS41-CP□.”
IZF21/31 series ionizers are marked with “ADJUST” on the front of the product.
For details on adjusting the offset voltage, refer to the operation manual.
The IZF series operation manual can be found here.
The IZF21/31 fans offer market-leading performance, functionality, size and accessories. Treat an area up to 2' x 8', neutralizing static as rapidly as 0.5s while achieving a ±5V balance. 8 emitters provide high ion output, and reverse polarity each time power is supplied, increasing durability.
The IZF21/31 fans offer market-leading performance, functionality, size and accessories. Treat an area up to 2' x 8', neutralizing static as rapidly as 0.5s while achieving a ±5V balance. 8 emitters provide high ion output, and reverse polarity each time power is supplied, increasing durability.
Model: 31 (4.4 m³/min), Input/Output: P (PNP, Input, Output), Power Supply Cable, AC Adapter: w/Power Supply Cable, 3m, Bracket: B (w/Bracket), Automatic Cleaning Unit, Louver: W (w/Adjustable Louver), Filter: U (w/Filter)
Model: 4.4 m³/min, Input/Output: PNP, Input, Output, Power Supply Cable, AC Adapter: w/Power Supply Cable, 3m, Bracket: w/Bracket, Automatic Cleaning Unit, Louver: w/Adjustable Louver, Filter: w/Filter
Model: 21 (1.8 m³/min), Input/Output: P (PNP, Input, Output)
Model: 1.8 m³/min, Input/Output: PNP, Input, Output, Power Supply Cable, AC Adapter: -, Bracket: -, Automatic Cleaning Unit, Louver: -, Filter: -
Type: Fan Type, Indicator: Charged/Discharged Status / Cleaning / Error, Additional Function: Air Volume Adjustment / Error Signal Output, Air Flow/Consumption Amount(m3/min): 1.8, Ion Balance: ±5V, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: With power supply cable (3 m) / With
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): -, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): null~0.7, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: Power supply cable included (3 m) / with bracket, I/O specifications: NPN output
Type: Fan Type, Indicator: Charged/Discharged Status / Cleaning / Error, Additional Function: Air Filter / Air Volume Adjustment / Error Signal Output, Air Flow/Consumption Amount(m3/min): 1.8, Ion Balance: ±5V, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: With filter / With power