M1 IZS30 A0201 IZS30 (10 replacement felt pads) (With 1 felt pad, 1 rubber grindstone, and 2 replacement felt pads) A0202 IZS30 (1 replacement rubber grindstone) Felt Rubber grindstone 12 IZF21/31 Series Specifications Model IZF21-m IZF21-P IZF31-m IZF31-P NPN PNP NPN PNP Maximum air flow 1.8 m3/min 4.4 m3/min Applied voltage 5 kV Ion generation method Corona discharge type Method of applying
Cylinder port 4-J M MM BZ GB R TY TDe8 D EA E W FA AL C B A K F N N M TT S + Stroke H BY TX TZ ZZ + Stroke BW With rod boot 180, 200, 250 Z1+ l + 1/2 stroke BV BZ BG BE e 4-MA Effective thread depth MB (To attach eyebolt) f l 15 h + l ZZ1 + l + Stroke Bore size (mm) Stroke range (mm) J M AL B C E F FA GA K KA N A BA BB BC BD BG BE BZ BV BW BP D EA GB GC H MM P BY MB MA 125 140 160 180 200
(Rc, NPT, G) Cylinder port 4 x J M MM BZ GB R TDe8 D EA TY E C B W FA AL C A K F M TT N N B S + Stroke H BY TX TZ ZZ + Stroke BW For 180, 200, 250 Z1 + l + 1/2 Stroke With rod boot BV BZ BG BE e 4 x MA Effective thread depth MB (for holding eyebolt) f l ZZ1 + l + Stroke h + l (mm) Stroke range (mm) Bore size (mm) A AL B BABB BC BV BW BY BZ BP C D E EA F FA GAGB H P N K KA M J MM GC BD BG
P Encoder cable 4) Regenerative option lead Cooling fan Power supply BU BV BW 6) Cooling fan lead Thermal OHS1 OHS2 7) Thermal Note.
C Encoder P Encoder cable 4) Regenerative option lead Cooling fan Power supply BU BV BW 6) Cooling fan lead Thermal OHS1 OHS2 7) Thermal Note.
MY1B P . 8-11-16 MY1M P . 8-11-40 MY1C P . 8-11-56 MY1H P . 8-11-72 MY1CW P . 8-12-14 MY1MW P . 8-12-14 Stroke adjusting unit For applicable symbol, refer to the table below. Note) For MY1H, the parts are packed together when shipped. Stroke Note) Indicates the stroke prior to mounting the stroke adjusting unit.
A B c D E F H K lil N P O (Ihpth) Tol{ances Tolerances NCDBBlBWlO 1 . 1 4 0.750.98 !.
A B c D E F H K lil N P O (Ihpth) Tol{ances Tolerances NCDBBlBWlO 1 . 1 4 0.750.98 !.
Fan Type Ionizer IZF21/31 Series RoHS How to Order IZF 21 B Air suction side lter Model Nil None U With lter1 Symbol Max. air ow 21 1.8 m3/min 31 4.4 m3/min 1: Filter + Filter holder Automatic cleaning unit, Louver (Refer to page 12 for detail.)
Type: Fan Type, Indicator: Charged/Discharged Status / Cleaning / Error, Additional Function: Air Volume Adjustment / Error Signal Output, Air Flow/Consumption Amount(m3/min): 1.8, Ion Balance: ±5V, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: With power supply cable (3 m) / With
Model: 21 (1.8 m³/min), Input/Output: NPN, Input/Output, Power Supply Cable, AC Adapter: w/Power Supply Cable, 3m, Bracket: B (w/Bracket), Automatic Cleaning Unit, Louver: W (w/Adjustable Louver)
Port size Rc1/4, NPT1/4, G1/4(ISO1179) U P DOWN U P DOWN U P DOWN SET SET SET Model with initial display settings of PSI is also available as standard.
, Description (Pressure Switch for Vacuum) p. 22 Pressure Switch for Vacuum with Energy Saving Function Specifications, Internal Circuit and Wiring Example p. 23 Port Layout Standard Products p. 24 Option -D p. 26 Option -L p. 29 Construction p. 31 Replacement Parts for Single Unit / How to Order p. 32 Exploded View of Manifold p. 33 Dimensions p. 35 Electrical Wiring Specifications
P-D 1 P P C C G3 D (2) 1) G4 5m (1) 1.
P-D P P C C G3 D (2) G4 5m 5m (1) 1.
Output form O: 1SHOT output H: HOLD output C: COMPARE output Reading pre-scale setting Command Block # 0 0 P R [CR] Unit No. Command Check sum code Response Block # 0 0 P R [CR] Unit No. Command Response Status Check sum code data Response data details 1 0 0 0 0 0 1 1 Multiplication Pre-scale value Decimal point position Writing pre-scale setting Command Block # 0 0 P W [CR] Unit No.
No. )0 ,+O H C 29 - # 0 0 P R [CR] No.
Allow margins for safety when selecting the model 1 Read Before Using 002 220W Nil None P High head pump if it is to be used in any of the following conditions. Thank you for purchasing SMCs Thermo-con (hereinafter referred to as the product).