This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ELECTRODE NEEDLE ASSY, OTHERS, IZS/IZF IONIZER, 21, IZSE30 NO SIZE RATING, 0.73487 lb
surface)) Low-noise fan: 48 dB(A) (Measured at a distance of 300 mm from the workpiece), Rapid static neutralizing fan: 57 dB(A) Offset voltage (Ion balance): 13 V With alarms for Incorrect high voltage, Maintenance warning With flow rate adjustment function (IZF10R) Based on ANSI/ESD-STM3.1-2006 standards 6 C O N T E N T S IZF21/31 IZF10/IZF10R Technical Data IZF21/31 Series IZF10/IZF10R
(n: Integer from 1 to 34) (For 2, 3, 6, 11, 14, 19, 24, 31 and 34 for n, use a standard model.)
(A cord is attached to the AC adapter.) 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 O.D. mm 06 08 10 6 8 10 : With piping on one side : With piping on both sides Made to Order Specifications Contents Symbol Non-standard bar length Symbol for producible bar length: 460 + 60 x n (n: Integer from 1 to 34) (For 2, 3, 6, 11, 14, 19, 24, 31 and 34 for n, use a standard model.)
In an area where the product may receive direct impact or vibration. n. Areas where the product may be subjected to forces or weight that could cause physical deformation. 4) The product does not incorporate a protection to lightning surges. 5 - Doc. no. IZ*-OMT0002 Maintenance Warning 1) Perform maintenance regularly and clean the emitters.
Mounting bracket for series IZF10 Fan Ionizers Mounting bracket for series IZF10 Fan Ionizers ; Includes mounting hardware
AC Adapter for series IZF10 and IZS40 ionizers. Option with or without AC cord. Note: NOTcompatible with IZS41/42. AC Adapter for series IZF10 and IZS40 ; Optional AC cord ; Note: NOT compatible with IZS41/42
AC Adapter for series IZF10 and IZS40 ionizers. Option with or without AC cord. Note: NOTcompatible with IZS41/42. AC Adapter for series IZF10 and IZS40 ; Optional AC cord ; Note: NOT compatible with IZS41/42
Mounting bracket for series IZF10 Fan Ionizers Mounting bracket for series IZF10 Fan Ionizers ; Includes mounting hardware
For the IZF10/10R, the excess current on output circuit and incorrect high voltage alarms cannot be checked.
And for the IZF21/31, the excess current on output circuit, incorrect high voltage, power supply failure, fan motor failure, CPU failure, maintenance warning, emitter cartridge mounting failure, and automatic cleaning failure alarms cannot be checked.
For IZF10/10R series ionizers, the power cable connector used is an e-CON connector. e-CON connectors can be ordered individually using the part number “ZS-28-C.”
Connect the numbers on the connector body in the following manner: 1 to +24 VDC (brown), 2 to 0 V (blue), 3 to F.G. (green), and 4 to the error signal (purple).
type=GUIDE&id=IZF10-E" target="_blank">here.
The IZF10 is SMC's compact fan ionizer. The fan ionizer emits static eliminating ions using ambient air, suitable for when an air supply is inconvenient or unavailable. Treatment area can be up to 1200mm / 47 in away. The fan is operated by a power switch, with an ion balance adjustment trimmer in the back. Available with a low noise or rapid static elimination fan.
The IZF10R shares the same fan size and ±13V ion balance with the IZF10, with two new features. A new 4-speed fan adjuster knob is added, including one higher and one lower speed for faster neutralization and greater range, or quieter operation. In addition to the high current/high voltage switch output, a second output signal indicates when emitter maintenance is required.
The IZF10 is SMC's compact fan ionizer. The fan ionizer emits static eliminating ions using ambient air, suitable for when an air supply is inconvenient or unavailable. Treatment area can be up to 1200mm / 47 in away. The fan is operated by a power switch, with an ion balance adjustment trimmer in the back. Available with a low noise or rapid static elimination fan.
The IZF10R shares the same fan size and ±13V ion balance with the IZF10, with two new features. A new 4-speed fan adjuster knob is added, including one higher and one lower speed for faster neutralization and greater range, or quieter operation. In addition to the high current/high voltage switch output, a second output signal indicates when emitter maintenance is required.
Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: P (PNP Output), Power Supply Cable, AC Adapter: N (w/o Cable)
Air Volume: L (Low Noise Type, 0.46m³/min), Output: P (PNP Output), Power Supply Cable, AC Adapter: N (w/o Cable)
Air Volume: L (Low Noise Type, 0.46m³/min), Output: NPN Output, Power Supply Cable, AC Adapter: N (w/o Cable)