SMC Corporation of America
Elite Part Number Search
Search Results "IZF10-H"

, AC adapter Nil With power supply cable (3 m) Z With power supply cable (10 m) H*1 e-con connector Q With AC adapter (with AC cord) R With AC adapter (without AC cord) N None Output Nil NPN output P PNP output *1: A power supply connector for customers who prepare a cable 21 Fan Type Ionizer IZF10/IZF10R Series Accessories (for Individual Parts) IZF21/31 IZF10/IZF10R Technical Data Power

Every time the NDL key is pressed, the maintenance detecting level is changed from L (low), M (middle), and to H (high) in turn.

X14 1 1 1 1 2 2 3 3 4 5 7 7 IZD IZE IZH Drop prevention cover When attached to the body Transition wiring cable Remote controller/IZS41-RC IZS41 CF Transition wiring cable 02 05 08 Full length 2 m Full length 5 m Full length 8 m AC adapter For IZS40 IZF10 C AC adapter G1 G2 AC adapter + AC cord AC adapter (without AC cord) AC cord is only for use in Japan.

Enclosed or poorly ventilated areas. h. Locations which are exposed to direct sunlight or heat radiation. i. Areas where strong electromagnetic noise is generated, such as strong electrical and magnetic fields or supply voltage spikes. j. Areas where the product is exposed to static electricity discharge. k. Locations where strong high frequency is generated. l.

Mounting bracket for series IZF10 Fan Ionizers Mounting bracket for series IZF10 Fan Ionizers ; Includes mounting hardware

AC Adapter for series IZF10 and IZS40 ionizers. Option with or without AC cord. Note: NOTcompatible with IZS41/42. AC Adapter for series IZF10 and IZS40 ; Optional AC cord ; Note: NOT compatible with IZS41/42

AC Adapter for series IZF10 and IZS40 ionizers. Option with or without AC cord. Note: NOTcompatible with IZS41/42. AC Adapter for series IZF10 and IZS40 ; Optional AC cord ; Note: NOT compatible with IZS41/42

Mounting bracket for series IZF10 Fan Ionizers Mounting bracket for series IZF10 Fan Ionizers ; Includes mounting hardware


For the IZF10/10R, the excess current on output circuit and incorrect high voltage alarms cannot be checked.
And for the IZF21/31, the excess current on output circuit, incorrect high voltage, power supply failure, fan motor failure, CPU failure, maintenance warning, emitter cartridge mounting failure, and automatic cleaning failure alarms cannot be checked.

For IZF10/10R series ionizers, the power cable connector used is an e-CON connector. e-CON connectors can be ordered individually using the part number “ZS-28-C.”
Connect the numbers on the connector body in the following manner: 1 to +24 VDC (brown), 2 to 0 V (blue), 3 to F.G. (green), and 4 to the error signal (purple).

The IZF10 is SMC's compact fan ionizer. The fan ionizer emits static eliminating ions using ambient air, suitable for when an air supply is inconvenient or unavailable. Treatment area can be up to 1200mm / 47 in away. The fan is operated by a power switch, with an ion balance adjustment trimmer in the back. Available with a low noise or rapid static elimination fan.

The IZF10R shares the same fan size and ±13V ion balance with the IZF10, with two new features. A new 4-speed fan adjuster knob is added, including one higher and one lower speed for faster neutralization and greater range, or quieter operation. In addition to the high current/high voltage switch output, a second output signal indicates when emitter maintenance is required.

The IZF10 is SMC's compact fan ionizer. The fan ionizer emits static eliminating ions using ambient air, suitable for when an air supply is inconvenient or unavailable. Treatment area can be up to 1200mm / 47 in away. The fan is operated by a power switch, with an ion balance adjustment trimmer in the back. Available with a low noise or rapid static elimination fan.

The IZF10R shares the same fan size and ±13V ion balance with the IZF10, with two new features. A new 4-speed fan adjuster knob is added, including one higher and one lower speed for faster neutralization and greater range, or quieter operation. In addition to the high current/high voltage switch output, a second output signal indicates when emitter maintenance is required.

Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): -, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): null~0.7, Power Supply: DC24V, Accessories/options: ordered separately: Without power supply cable / without bracket, I/O specifications: PNP output, Bar length(mm)

Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: NPN Output, Power Supply Cable, AC Adapter: N (w/o Cable)