Body Size: 30 (4000 L/min), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 3 (3/8", 2000, 3000)

Body Size: 30 (4000 L/min), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 3 (3/8", 2000, 3000)

Body Size: 30 (4000 L/min), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 4 (1/2", 3000)

Body Size & Pressure Range: Body Size: 4000 L/min; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: Rc, Port: 3 [3/8, (2000, 3000)], Made to Order: -

Body Size & Pressure Range: Body Size: 4000 L/min; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: NPT, Port: 3 [3/8, (2000, 3000)], Made to Order: -

Body Size & Pressure Range: Body Size: 4000 L/min; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: NPT, Port: 4 [1/2, (3000)], Made to Order: -

X2 (Port4 input) X4 (Port 4 input) 19 Reserved (Port 3) 20 to 35 Port 4 IO-Link process data -85No.PF-OMA1007-B Output mapping AMS Base Bit Byte 7 6 5 4 3 2 1 0 Isolation input signal for NO system Isolation input signal for NC system 0 Reserved F-Standby Standby 1 Reserved Port 4 Digital Output Reserved 2 Port 4 IO-Link process data : 17 18 Wireless Remote 1 : : : Wireless Remote 10 Byte

Bit 11 Internal communication error 0x1813 Occurs when an internal communication error . 4 Bit 10 Alarm generation Bit 8~9 of Byte 4 and Bit 7~4 of Byte 5 It is set when any of them is ON, otherwise it is 0. Bit 9 Excessive power supply voltage 0x5110 Occurs when the power supply voltage exceeds the specification.

PD IN (from ITV) 15*3 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Output pressure (13BIT) On hold*4 BDC1 Value 100% F.S. is indicated using 12 BITs, from the 3rd BIT to the 14th BIT. *3 Setting up to 120% F.S is possible by using the 15th BIT (However this is out of warranty). *4 0 is returned in an unused area.

Type1: EX600-SPN (32 coils) --Occupies 4 bytes for output (No diagnostic data) Type2: EX600-SPN (32 coils, Status) --Occupies 4 bytes for output and 4 bytes for diagnostics (input) (1) (2) (3) (4) -61No.EX-OMQ0016 Setting of parameters Setting of system parameters (1)Click the EX600-SPN# icon in the [HW Config] screen, and double-click the unit that needs a change in the parameters.

1)[HW Config]EX600-SPN# (2)[Configuration table]EX600-SPN# (3)[Hardware Catalog]0 [Configuration table]1 1=2 0=1 (4)SI SI2SI Type1: EX600-SPN (32 coils) ---4 Type2: EX600-SPN (32 coils Status) ---4 4 (1) (2) (3) (4) -61No.EX-OMQ0015CN (1)[HW Config]EX600-SPN#[Configuration table][ ][Properties] (2)[Parameters] (3)[Value] (4)[OK]PLC (1) (1) (2) (2) (3) (4) (3) -62No.EX-OMQ0015CN FSU(

"EX260-SPN (EX260-SPN-1, EX260-SPN-2, and so on)" should be entered in the Device name box for each EX260-SPN1/2 or EX260-SPN3/4 set with the hardware configuration. The same name must be used for the connected SI unit device name (page 18) and the device name set in the hardware configuration.

Type1: EX600-SPN (32 coils) --Occupies 4 bytes for output (No diagnostic data) Type2: EX600-SPN (32 coils, Status) --Occupies 4 bytes for output and 4 bytes for diagnostics (input) (1) (2)(3) (5) (4) -76No.EX-OMY0027 4.

[Mode] will be set to that setting. (4) When you press [Go Online], the "Synchronize Port Configuration" screen will appear. (5) Press [write to master] to apply the setting to the EX600-L#B1. (1)(4) (2) (3) (5) * When the SI unit is EX600-SPN3/4 or EX245-SPN#A, use the configuration software of the PLC to change the parameters of EX600-L#B1 and EX245-L#1. * Parameters cannot be changed by