SMC Corporation of America
Elite Part Number Search
Search Results "ITV3050-044N2"

Part Number Description: COVER (ITV3050-33N4CN4-X15)   Product Line: I   Product Line Description: INSTRUMENTATION   Family Code: 824   Family Description: IT4000/ITV3000 E/P REGULATOR   Class Code: F1   Part Code: 2   Reference Code:  J   Click here to report information errorImage shown may not match exact part number

4 0 N 2 B S X80 2 0 3 0 ITV 33 DeviceNet compatible Model 2000 type 3000 type 2 3 Thread type Pressure range Rc(PT) NPT NPTF G(PF) Nil N T F Cable connector type 0.005 to 0.1MPa 0.005 to 0.5MPa 0.005 to 0.9MPa 1 3 5 Without Straight type 3m Nil S Option (bracket) Port size Without bracket Flat bracket L-bracket Nil B C 1/4 3/8 2 3 Specifications ITV2050 ITV3050 ITV2030 ITV3030 ITV2010 ITV3010

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: IL (I/O-Link), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: Rc(PT), Port Size: 4 [1/2 (3000)], Accessory: None, Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 4 (PSI)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: IL (I/O-Link), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: Rc(PT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: S (Straight Style 3m), Pressure Display Unit: 4 (PSI)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: IL (I/O-Link), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 4 [1/2 (3000)], Accessory: B (Flat Bracket), Cable Connector: N (w/oCable Connector), Pressure Display Unit: 4 (PSI)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 2 (Switch Output NPN), Thread: N (NPT), Port Size: 4 [1/2 (3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 5 (kPa)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 1 (Current Style 0~20mADC), Monitor Output: 3 (Switch Output PNP), Thread: N (NPT), Port Size: 4 [1/2 (3000)], Accessory: None, Cable Connector: S (Straight Style 3m), Pressure Display Unit: 5 (kPa)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: F [G(PF)], Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 5 (kPa)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: F [G(PF)], Port Size: 4 [1/2 (3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 5 (kPa)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: F [G(PF)], Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 3 (Bar)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 53 (16 Points Preset Input - PNP Output), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: F [G(PF)], Port Size: 4 [1/2 (3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: N (NPT), Port Size: 3 [3/8 (2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 3 (Bar)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: N (NPT), Port Size: 3 [3/8 (2000,3000)], Accessory: C (L Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 4 (PSI)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: IL (I/O-Link), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector)

Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: Rc(PT), Port Size: 4 [1/2 (3000)], Accessory: B (Flat Bracket), Cable Connector: N (w/oCable Connector)

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output. The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available