SMC Corporation of America
Elite Part Number Search
Search Results "ITV1050-SPN-1-DUX02357"

Body Size: 10 (200 L/min [ANR]), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 10 (200 L/min [ANR]), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 1 (1/8", 1000)

Body Size: 10 (200 L/min [ANR]), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 2 (1/4", 1000, 2000)

Body Size & Pressure Range: Body Size: 200 L/min [ANR]; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: -

Body Size & Pressure Range: Body Size: 200 L/min [ANR]; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: NPT, Port: 1 [1/8, (1000)], Made to Order: -

Body Size & Pressure Range: Body Size: 200 L/min [ANR]; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: NPT, Port: 2 [1/4, (1000, 2000)], Made to Order: -

Body Size: 10 (200 L/min [ANR]), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 1 (1/8", 1000)

Body Size & Pressure Range: Body Size: 200 L/min [ANR]; Pressure Range: 0.005~0.5Mpa, Protocol: PROFINET, Thread: Rc, Port: 1 [1/8, (1000)], Made to Order: -

Product ID ITV1010-IO-X395 *1 ITV1030-IO-X395 *1 ITV1050-IO-X395 *1 ITV2010-IO-X395 *1 ITV2030-IO-X395 *1 ITV2050-IO-X395 *1 ITV2090-IO-X395 *1 ITV3010-IO-X395 *1 ITV3030-IO-X395 *1 ITV3050-IO-X395 *1 ITV3050-IOF3N-DIT00375 *1: This becomes product ID added since FW Ver1.2.

1 A Q a q 0 0 1 0 2 STX DC2 2 B R b r 0 0 1 1 3 ETX DC3 # 3 C S c s 0 1 0 0 4 $ 4 D T d t 0 1 0 1 5 % 5 E U e u 0 1 1 0 6 & 6 F V f v 0 1 1 1 7 7 G W g w 1 0 0 0 8 ( 8 H X h x 1 0 0 1 9 ) 9 I Y i y 1 0 1 0 10 * : J Z j z 1 0 1 1 11 + ; K [ k { 1 1 0 0 12 , < L l | 1 1 0 1 13 = M ] m } 1 1 1 0 14 . > N ^ n 1 1 1 1 15 / ?

Program Description SPN(500) STA(200) STB(300) MOVI(600) TRIPI(300) OUTON(1) SPN(700) MOVIA(700) TRIPI(300) OUTOF(1) STOP Speed (Motor speed) Acceleration time constant Deceleration time constant Incremental move command Incremental trip point Program output 1 (OUT 1) is turned ON.

Content 0 1: There is an error in unit 0. 1 1: There is an error in unit 1. 2 1: There is an error in unit 2. 3 1: There is an error in unit 3. 4 1: There is an error in unit 4. 5 1: There is an error in unit 5. 6 1: There is an error in unit 6. 7 1: There is an error in unit 7. Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.

][Edit Ethernet Node][Device name] (4)[Assing IP address via IO controller] (5)[OK] (1) (2) (3) (4) (5) -60No.EX-OMQ0015CN (1)[HW Config]EX600-SPN# (2)[Configuration table]EX600-SPN# (3)[Hardware Catalog]0 [Configuration table]1 1=2 0=1 (4)SI SI2SI Type1: EX600-SPN (32 coils) ---4 Type2: EX600-SPN (32 coils Status) ---4 4 (1) (2) (3) (4) -61No.EX-OMQ0015CN (1)[HW Config]EX600-SPN#[Configuration

"EX260-SPN (EX260-SPN-1, EX260-SPN-2, and so on)" should be entered in the Device name box for each EX260-SPN1/2 or EX260-SPN3/4 set with the hardware configuration. The same name must be used for the connected SI unit device name (page 18) and the device name set in the hardware configuration.

Type1: EX600-SPN (32 coils) --Occupies 4 bytes for output (No diagnostic data) Type2: EX600-SPN (32 coils, Status) --Occupies 4 bytes for output and 4 bytes for diagnostics (input) (1) (2)(3) (5) (4) -76No.EX-OMY0027 4.

Tab name Outline 1 Common Shows specific information such as the vendor ID of the EX600/EX245. 2 Port Config Shows information on devices connected to the ports of the EX600-L#B1 or EX245-L#1. 3 Settings Shows parameter setting information for the EX600-L#B1. Note: EX600-SEC3/SEC4 and EX245-SPN#A dont support the Settings tab. 8.3.