SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-02-AB-MLB"

0 1 Standard Micro load Port size Nil 02 N02 With gasket Rc 1/4 NPT 1/4 16-9-3 2 Series IS3000 Construction Precautions IS3000-02/3010-02 (Rc 1/4 thread) Be sure to read before handling.

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration

Port size Rc1/4, NPT1/4, G1/4(ISO1179) Plain Gray Orange PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH 16-2-45 2 2-color Display Digital Pressure Switch/For Air Series ISE70 How to Order ISE70 1MPa 02 43 M Piping Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

(17) 0 R www.smcworld.com 0x0012 (18) 0 R ISE70-02-L2 0x0013 (19) 0 R ID ISE70-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.

access lock 0x0 Refer to "Device Lock" on page 66. 0x000C (16) 0 R Vendor name SMC Corporation 0x0010 (17) 0 R Vendor text www.smcworld.com 0x0011 0x0012 (18) 0 R Product name Example ISE70-02-L2 (19) 0 R Product ID Example ISE70-02-L2 0x0013 (20) 0 R Product text Pressure sensor 0x0014 Initial value is indicated as 8-digit. 16 octets fixed character string (21) 0 R Serial number Example

ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with ISE70) Symbol Description B Bracket B L2 IO-Link

ISE70 (Air) ISE75 (Fluid) ISE75H (Fluid) Temperature characteristic (25 C reference: Within operating temperature range) 2%F.S. 3%F.S.

Nm 1.52 FG *() 6 33 2 () ( etc.) 10 m10 m DC(-)() -6No.PS-OMH0002CN-D * () CE (FKM) * 2030 1 LCD * ()(), (ISE70 ) O -7No.PS-OMH0002CN-D ISE ISE ISE ISE ISE ISE ISE ISE 70 01 MPa 02 43 70 75H 02 43 2 75 010 MPa A 75H 015 MPa 1 02 Rc1/4 N02 NPT1/4 S M12 (5m) F02 G1/4(ISO1179) L M12 (5m) 1 27 2 NPN 2 M SI 2 43 NPN 1 1 PNP 1 P psi() 1 65 PNP 1 1 2MPa 67 2 PNP 2 ZS-31-A A

Example) G36-P4-01-X30 ISA2 ISA2 2 Port Solenoid Valve Regulator PSE VCA27A S 5 DL 02 4 Q AR 20 02 1 B IS Port size Voltage CE compliant 02 02N 02F Rc 1/4 NPT 1/4 G 1/4 Thread type ISG 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Nil N F Rc NPT G ZSM1 Throttle Nil S B K Without throttle and manual lock With throttle With manual lock With manual lock and throttle Semi-standard