Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover,
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: w/o Operation Manual,
0oi q w e r t y u i !1 !2 No.
If using straight entry piping, the material and tubing need to be taken into consideration when deciding panel cut-out spacing. 2 If a bend (R) is used, limit it to R3 or less. 3: Suitable for panel thickness of 1 to 3.2 mm.
L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I 1 W Z (2 m) (2 m) + () 2 R
Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended
Safety Instructions Bracket A ISE20C(H) Display color Output ON: Green/Output OFF: Red (Linked to OUT1) P psi ZSE20C(F) : Arbitrary display OUT1 hysteresis OUT1 set value Mode display These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: w/o Operation Manual
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount Adapter + Front
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover,
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: w/o Operation Manual,