Search Results "ISE20CH-L-N02L"

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. PRESSURE SWITCH, ISE1-6. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 117.00000 lb. N59.

(Refer to p. 24.) * Not applicable to the rated pressure 0.1 to 2 MPa specifications (ISE20CH). * A restrictor (equivalent to -X510) is installed inside the fitting. (Piping specifications A2(L) and B2(L) are excluded.)

Piping/weight specifications Product No. 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) Port size R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 fluid contact Materials in part Pressure-sensing part Pressure sensor: SUS630, Fitting: SUS304 Body (Rear piping) 51 g 51 g 48 g 47 g 54 g 46 g Weight Body (Bottom piping) 77 g 78 g 74 g 65 g 81 g 72 g Lead wire with connector +39 g Leakage 1 x 10-5Pa m3/s 1 x 10

() () () () 3 MPa,kPa,kgf/cm 2,bar,psi,InHg, mmHg MPa,kPa,kgf/cm 2,bar,psi LCD 3 (X2) 1)/ 2) 1)4 7 2)4 (1 11 7 ) ON OUT1OUT2 4 0,10,50,100,500,1000,5000 ms IP65 AC250 V 1 2 M(DC50 V ) -550 -1060 () 3585RH() UL/CSA(E216656)CE(EMC RoHS ) 2 m 1(0 ms) 2 3MPa/kPa 490% 5 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 SUS630SUS304 () 51 g 51 g 48 g

(Piping specifications A2(L) and B2(L) are excluded.) ZSP PS Specifications ISA Model 500 kPa ZSE80(F) 1.5 MPa ISE80 PSE Withstand pressure Applicable fluid Fluids do not corrode stainless steel 316L IS Models other than above are the same specifications as standard.

ON-OFF () 1 L/min ,10 11 12 1 L/min SI SI ON-OFF ON 0 ripple -15No.PF-OMO0004CN-E AB.

min Instantaneous flow 2 to 210 L/min Set flow rate range Accumulated flow 0 to 999,999,999 L Flow Instantaneous flow 1 L/min Minimum setting unit Accumulated flow 1 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse Accumulated value hold 2 Every 2 minutes or every 5 minutes.

Before Use Digital Pressure Switch ZSE20C(F)-L/ISE20C(H)-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.

Mounting with bracket Fix the bracket to the Pressure switch with the set screws M3 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm. -14No.PS-OMM0003-J Mounting with panel mount adapter -15No.PS-OMM0003-J Piping Connection using screw type piping Connect suitable piping to the port.

VCRSwagelok Company -6No.PS-OMM0002CN-F * 6 33 () () 10m DC(-)() * ( ) () CE -7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y K + T + 2 02 R1/4 N02 NPT1/4 F02* G1/4 G01 Rc1/8 A2 URJ1/4 B2 TSJ1/4 A (ZS-24-A/ZS-35-A) B *(ZS-24-D) C D + F02 ISO228-1 1 *1 L

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Current pressure value (Main display) Output mode Hysteresis mode Item (Sub display (left)) Set value or peak/bottom value (Sub display (right)) Reversed output Normal output [F 0] Units selection function ISE20C: 0.500 MPa/ZSE20C: -50.5 kPa/ ZSE20CF: 50.0 kPa/ISE20CH: 1.000 MPa Default setting Units specification Pressure range Pressure setting Sub display In measurement mode, the display

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual