B -15No.PS-OMU0005CN-C (a)(a) (b) (ZS-46-B) +(ZS-46-D) 90 -16No.PS-OMU0005CN-C (-M5) 1/6~1/4 1~1.5Nm (ZS-46-N) -01-N01 23 3~5 Nm -C4L-C6L 1/61/4 1~1.5Nm -17No.PS-OMU0005CN-C -18No.PS-OMU0005CN-C () TU0425( 42.5) -19No.PS-OMU0005CN-C FG -20No.PS-OMU0005CN-C Z/ISE20B(F)-S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -X () -S

: Process Data p. 17 Functions p. 17 Internal Circuits and Wiring Examples p. 18 Dimensions p. 20 7 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20 Series IP65 2 outputs ZSE/ISE20B p. 13 IP65 2 outputs ZSE/ISE20C p. 24 IO-Link IP65 1 output ZSE/ISE20B-L p. 15 Air General fluids For vacuum pressure For compound pressure For positive pressure For vacuum pressure For compound

Settable range of user set value Settable value range Range Lower limit Upper limit -10..+10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..+5 V -5.25 to +5.22 V -5.22 to +5.25 V -20..+20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00

Flat pad P. 11 3.5 x 7 4 x 10 4 x 20 4 x 30 5 x 10 5 x 20 5 x 30 6 x 10 6 x 20 6 x 30 8 x 20 8 x 30 W P. 17 Oval pad 3.5 x 7 2 x 4 4 x 10 U H P. 33 HT P. 33 Heavy-duty pad HB P. 35 HW P. 36 U P. 27 Mark-free pad H P. 28 Related pad S Sponge pad P. 30 Resin attachment K P. 29 Pad with ball spline buffer U P. 24 H P. 37 Heavy-duty ball joint pad HB P. 43 Cyclone pad (Non-contact pad) Made

Flat pad P. 11 3.5 x 7 4 x 10 4 x 20 4 x 30 5 x 10 5 x 20 5 x 30 6 x 10 6 x 20 6 x 30 8 x 20 8 x 30 W P. 17 Oval pad 3.5 x 7 2 x 4 4 x 10 U H P. 33 HT P. 33 Heavy-duty pad HB P. 35 HW P. 36 U P. 27 Mark-free pad H P. 28 Related pad S Sponge pad P. 30 Resin attachment K P. 29 Pad with ball spline buffer U P. 24 H P. 37 Heavy-duty ball joint pad HB P. 43 Cyclone pad (Non-contact pad) Made

Flat pad P. 11 3.5 x 7 4 x 10 4 x 20 4 x 30 5 x 10 5 x 20 5 x 30 6 x 10 6 x 20 6 x 30 8 x 20 8 x 30 W P. 17 Oval pad 3.5 x 7 2 x 4 4 x 10 U H P. 33 HT P. 33 Heavy-duty pad HB P. 35 HW P. 36 U P. 27 Mark-free pad H P. 28 Related pad S Sponge pad P. 30 Resin attachment K P. 29 Pad with ball spline buffer U P. 24 H P. 37 Heavy-duty ball joint pad HB P. 43 Cyclone pad (Non-contact pad) Made

MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

kPa -0.1001.000 MPa / 10.0-105.0 kPa -105.0105.0 kPa -0.1051.050 MPa / 0.1 kPa 0.001 MPa 500 kPa 1.5 MPa DC1224 V10 (p-p)10 35 mA 2F.S. 1digit(253 ) 0.2F.S.1 digit 2.5F.S.(253 ) 1F.S. 2%F.S.(25) NPN PNP 2 80 mA (NPN) 28 V () 1 V (80 mA ) 1 1.5 ms (20,100,500,1000,2000,5000 ms ) 0 2 15 V 0.65 V 1 k 420 mA 2.420 mA 12 V 300 24 V 600 50 0.4 V 5 ms -75No.PS-OMU0002CN-D

10(P-P)10() 40 mA NPN PNP 1 NPN PNP 2 80 mA 28 V(NPN ) 1 V (80 mA ) 2.5 ms (2010050010002000 ms ) 0.2F.S. 1 digit 0 1 () 15 V2.5F.S. 0.65 V2.5F.S. 2 1F.S. 1 k () 420 mA2.5F.S. 2.420 mA2.5F.S. 1F.S. 12 V 300 24 V 600 50 3 4 7 LCD 2 (/) 2 F.S.1 digit(253 ) ON OUT1 OUT2 IP40 050 -1060 () 3585RH AC1000 V 1 50 M (DC500 V ) 2F.S.(25 ) 3 3.52 m 4 0.15 mm 2(

Current output Load impedance Maximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green) 2% F.S. 1 digit (Ambient temperature of 25 3C) Lights up when switch output is turned ON.

-100.0100.0 kPa T 2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD

Example: Analog output = 1 to 5 [V] F.S. = 5 [V] 1 [V] = 4 [V] 3 [% F.S.] = 4 x 0.03 = 0.12 [V] The output error induced by the temperature change can be as much as 0.12 [V].

How To Order,/NVV4Zl Manifold Nvv4zl ::P r =*na, acc$ory F : Mounting brackets 'A .v?

IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.

Maximum load impedance: Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Minimum load impedance: 50 Reduce/Increase supply pressure to within the regulating pressure range. Applied pressure error Brown DC(+) Supply pressure is below the minimum regulating pressure.