The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CB, ISE2 1/8INCH NPT VERSION, .07716 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CB, ISE2 1/8INCH NPT VERSION, .20542 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics
Pressure Range: 0~1MPa, Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: CN (w/o Connector)
Pressure Range: 0~1MPa, Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: CL (Connector Style Lead Wire Length 3.0m)
Pressure Range: 0~1MPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: w/o Connector
Pressure Range: 0~1MPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: Connector Style Lead Wire Length 3.0m
Series IDU High inlet air temperature type Rated inlet air temperature: 55C [Max. inlet air temperature: 80C] Refer to SMC website for details.
Time [s] Method 2: Calculation T1 T2 T3 T4 T5 Cycle time T can be found from the following equation. T6 T = T1 + T2 + T3 + T4 [s] Calculation example) T1 to T4 can be calculated as follows. L : Stroke [mm] V : Speed [mm/s] a1: Acceleration [mm/s2] a2: Deceleration [mm/s2] T1 and T3 can be obtained by the following equation.
Calculation example) T1 to T4 can be calculated as follows. L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be obtained by the following equation.
JOG and constant rate movement, return to origin, test operation and testing of compulsory output can be performed. 57 Series LEC Teaching Box/LEC-T1 How to Order LEC T1 3 J G Enable switch (Option) Teaching box Enable switch S None Equipped with enable switch Nil Cable length 3 3 m Interlock switch for jog test function Stop switch Initial language J E Japanese English Stop switch G Equipped
-25 NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ZSE401 T1-26 Vacuum Analog output 1~5V (+ 5%F.S.), load impedance : 1k ZSE401 T1-65 PNP output PNP open collector 80mA ISE4L01 T1-25 Positive Pressure NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ISE4L01 T1-26 100kPa Analog output 1~5V (+ 5%F.S.), load impedance: 1k ISE4L01 T1-65 (14.5PSI) Type
JOG and constant rate movement, return to origin, test drive and testing of forced output can be performed. 569 B LEC Series Teaching Box/LEC-T1 RoHS How to Order LEC T1 3 J G Enable switch (Option) Enable switch Teaching box Nil None S Equipped with enable switch Cable length [m] 3 3 Interlock switch for jog and test function Stop switch Initial language Stop switch J Japanese E English
-02 Performance/Specifications General specifications LC5-1-T1-02 Part no.
Conversely, due to the operation of the switching valve that occurs after a certain length of time, T1 becomes reactivated and T2 assumes the adsorption state. This process is repeated to continuously provide dry air.
Power supply 11) 100/110V AC (50/60Hz) 200/220V AC (50/60Hz) 21) 1) Consult SMC if the supply voltage for LC1-1HV1 will be 110V AC or more, or the supply voltage for LC1-1HV2 will be 220V AC or more. or LC1-1-T1(Teaching box) are required.