Fluororubber is used for rubber seal materials. 80 IR 0 Ozone resistant X170 IR 0 Compatible with modular connection brackets Modular Combination Example Description Applicable model IR100--X170 AF20-A AFM20-A Y200-A Y200T-A IR20--X170 AF30-A AFM30-A Y300-A Y300T-A IR30--X170 AF40-A AFM40-A Y400-A Y400T-A qRegulator wAir filter eMist separator rInterface tInterface with bracket Note 1) The
, HNBR 9 Body Aluminum die-casted 799 IR1000-A/2000-A/3000-A Series Construction Basic type (Knob): IR10l0-A r r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000
If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. in minor or moderate injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Rc1/8 [2 ] 0.64 (1) (0.1MPa) (2) IR3000:0.2MPa (3)2 ON-OFF () (4) 4- (C) (C) (A) (A) (C) (A) (C) BLEED SUP OUT SU P N/ M Pa/ ( S) N N m 1 1 M Pa/m ( ) m 2 M Pa M Pa (A) /N (B) / ( ) m 2 ( A ) m 2 5- I R 3 0 0 1 SUP OUT 2 3%F.S. 3 R B(P36203018) G 2 3 RcF N IR3000G43-2-01 G43-P2-N01-X30 IR3010G43-4-01 G43-P4-N01-X30 IR3020G43-10-01 G43-P10-N01-X30 02:1/4 03
, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)
M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .
1 8 R 1 4 R 3 8 04F 06F 08F 01S 02S 03S Red R (Option) 2(A) port size 04F 06F 08F 4 6 8 *Specifications and dimensions for the 90-series are the same as standard products.
Description IR1000 IR1020 IR2000 IR2010 IR2020/2120 IR3000 IR3010 IR3020/3120 IR1010 P362030-201 Bracket P36202028 P36201023 Pressure gauge234 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-4-01 G43-10-01 G33-2-01 G43-4-01 G33-4-01 1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: F (G), Port Size: 03 (3/8), Option: B (w/Bracket), Semi-standard: None
Body Size: 3, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: G, Port Size: 3/8, Option: w/Bracket, Semi-standard: None
Body Size: IR3000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: F [G(PF)], Port Size: 03 [3/8 (IR3000 Only)], Accessory: Bracket, Temperature Environments: -, Suffix: -, Made to Order: -
This is a legacy product, and replaced byAL30-F03B-A, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, EA, AL MASS PRO 3/8 MODULAR (PT), 1.46347 lb
This is a legacy product, and replaced byVHS40-F03B, VALVE, 3 PORT LOCK OUT, VALVE, VHS HAND VALVE, GA, VHS BODY PT 3/8NPT (F), .76240 lb
This is a legacy product, and replaced byASS300-F03B, SPEED CONTROL, SLOW START, AIRLINE EQUIPMENT, ASS 3/8INCH STANDARD (PT), .52717 lb
This is a legacy product, and replaced byVHS30-F03B, VALVE, 3 PORT LOCK OUT, VALVE, VHS HAND VALVE, G7, VHS BODY PT 3/8NPT (F), 0.56735 lb
This is a legacy product, and replaced byVHS30-F03B, VALVE, LOCK-OUT, EUROPEAN *LQA, VALVE, VHS HAND VALVE, H7, VHS BODY PT 3/8, 0.61729 lb
For the IR400-02/03/04□□: IR3000-02/03/04□□-A
For the IR401-02/03/04□□: IR3010-02/03/04□□-A
For the IR402-02/03/04□□: IR3020-02/03/04□□-A
For the IR412-02/03/04□□: IR3120-02/03/04□□ (IR-A series air operated regulators will be available at a later date.)
Note) Select option “H” when panel mounting the product.
(e.g., IR3020 sensitivity: 1.6 kPa←800 kPa x 0.2% [800 kPa = 0.8 MPa])
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 04 (1/2), Option: None, Semi-standard: R (Flow Direction: Right to Left)