SMC Corporation of America
Elite Part Number Search
Search Results "IR1020-01H-A"

Fluororubber is used for rubber seal materials. 80 IR 0 Ozone resistant X170 IR 0 Compatible with modular connection brackets Modular Combination Example Description Applicable model IR100--X170 AF20-A AFM20-A Y200-A Y200T-A IR20--X170 AF30-A AFM30-A Y300-A Y300T-A IR30--X170 AF40-A AFM40-A Y400-A Y400T-A qRegulator wAir filter eMist separator rInterface tInterface with bracket Note 1) The

When a system hazard can be expected due to a drop in vacuum pressure caused by power loss or vacuum pump trouble, install a safety circuit and configure the system so that it can avoid the danger. 2. When a system hazard can be expected with a malfunction of the vacuum regulator, install a safety circuit and configure the system so that it can avoid the danger. 1.

If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.

IR-A IR-A IR IRV Series Variations VEX Series Model Set pressure range (MPa) Port size SRH IR1000-A IR1000-A 0.005 to 0.2 SRP SRF IR1010-A 0.01 to 0.4 1/8 ITV IR1020-A 0.01 to 0.8 Basic Type (Knob) IC IR2000-A IR2000-A 0.005 to 0.2 ITVH IR2010-A 0.01 to 0.4 1/4 ITVX IR2020-A 0.01 to 0.8 PVQ VY1 IR3000-A IR3000-A 0.01 to 0.2 VBA VBAT IR3010-A 0.01 to 0.4 1/4, 3/8, 1/2 AP100 IR3020-A 0.01 to

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

(IR1000:F.S.=0.2MPa,IR1010:F.S.=0.4MPa,IR1020:F.S.=0.8MPa) ) F.S. (2) (3) (4) 0.010.8MPa(IR1000 0.005MPa) 1 IR1000 IR1010 IR1020 [MPa] MAX. 1.0 [MPa] () 0.05 [MPa] 0.0050.2 0.010.4 0.010.8 0.2% 0.5% 4.4L/min(ANR) [1.0MPa ] -560 Rc1/8 Rc1/8 [2 ] 0.14kg (1) (0.05MPa) (2) IR1000:0.2MPa (3)2 ON-OFF () (4) -4- (C)2 (C) (A) (A) (C) (A) (C) BLEED SUP(1) OUT(2) SUP N

Classification Object Class Instance Identity 01h 01h Message Router 02h 01h DeviceNetTM 1 03h 01h DeviceNetTM object Connection 05h 03h Register 07h 02h Acknowledge Handler 2Bh 01h Map 65h 01h System 66h 01h Digital Input Unit 6Ah 01h to 09h 2 Digital Output Unit 6Bh 01h to 09h 2 DeviceNetTM extended object library 1 SI Unit 6Ch 01h Analogue Input Unit 6Dh 01h to 09h 2 Analogue Input/Output

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Caution : CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

66h 01h 3 67h 01h0Ah 3 77h 01h0Ah TM2 DeviceNet 3 78h 01h0Ah 3 (1) 79h7Fh 01h0Ah 3 (2) 83h8Ah 01h0Ah 1Quick Connect(Attribute 0Ah) 2 3 2 2 02h3 2 03h 0 1 2 3 4 5 AXA DYB DYB DXB DXD SDNA SI (32 ) 2 01h 01h 02h 01h 02h 01h 3 01h 02h 03h 04h 05h 06h -65No.EX-OMN0029CN-D Map (Class65h)[DeviceNet TM1] Instance Attribute Access Name Type Description/Value 01h 64h Get Input Data Size UINT

8-40 8 MECHATROLINK-II Commands 8.11.13 Read Parameters (PRM_RD: 01H) Send a PRM_RD command to read out parameters. (1) PRM_RD Command (01H) The specifications of the PRM_RD command are described below.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

A 2 A Power supply (Output) 24 VDC +10/-5%, 24 VDC +10/-5%, 8 A DC24 V +10/-5%, 4 A 2 A Enclosure IP67 (With manifold assembled) 1 Environment Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85%R.H.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .

(When L/A IN LED is OFF.) (2)Check that the connectors of L/A IN and L/A OUT communication cables are connected and there are no broken wires. (3)Keep noise sources away from the communication cable. L/A IN and L/A OUT LEDs are OFF. LINK has not yet been established. 11 : The L/A OUT LED will be OFF if the BUS OUT connector is not used.