Regulator, Pressure Boosting Valve: Controller, Pressure Range: 0.5 MPa, Output Specification: NPN open collector output, Sensor: Built-in sensor type, Mounting specification: Panel mount, Protective cover: With protective cover
Index Name / Meaning Type Value 90A0:0 Diag.: Module identification USINT 10 90A0:01 Address of the module UINT 10 90A0:09 Module PDO group UINT 0 90A0:0A Module ident DINT 256 or 257 -95No.EX-OMO0027-A Modular Device Profile Table.
Single numerical data instructions (1 Stations occupied) [Remote IO] PLC memory PLC memory address Signal name address Signal name Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG(-) 0E ESTOP 0E JOG(+) 0F ALARM 0F FLGTH 1A to 10
When the position status is not established, this terminal is OFF. 0A SETON 43 - The condition when the INP output is ON depend on the electric actuator action.
(P.32) (1) [IO] PLC PLC Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG(-) 0E ESTOP 0E JOG(+) 0F ALARM 0F FLGTH 101A CC-Link 101F CC-Link 1B READY 1C1F CC-Link (1) [] PLC RWr PLC RWw RWr bit RWw bit 0 (L) 0 1 (H) 1 (
Table 5.10 Selectable input devices Setting Input device (Note 1) value P S T 02 SON SON SON 03 RES RES RES 04 PC PC 05 TL TL 06 CR 07 ST1 RS2 08 ST2 RS1 09 TL1 TL1 0A LSP LSP LSP (Note 3) 0B LSN LSN LSN (Note 3) 0D CDP CDP 0E CLD 0F MECR 20 SP1 SP1 21 SP2 SP2 22 SP3 SP3 23 LOP (Note 2) LOP (Note 2) LOP (Note 2) 24 CM1 25 CM2 26 STAB2 STAB2 Note 1.
_ Notch depth selection 0: -40 dB 1: -14 dB 2: -8 dB 3: -4 dB 0h x _ _ _ For manufacturer setting 0h Table 5.4 Shaft resonance suppression filter setting frequency selection Setting value Frequency [Hz] Setting value Frequency [Hz] 00 Disabled 10 562 01 Disabled 11 529 02 4500 12 500 03 3000 13 473 04 2250 14 450 05 1800 15 428 06 1500 16 409 07 1285 17 391 08 1125 18 375 09 1000 19 360 0A
PB49]4(_ _ _ 1) _ _ x x 5.4 00h _ x _ _ 0:-40dB 1:-14dB 2:-8dB 3:-4dB 0h x _ _ _ 0h 5.4 [Hz] [Hz] 00 10 562 01 11 529 02 4500 12 500 03 3000 13 473 04 2250 14 450 05 1800 15 428 06 1500 16 409 07 1285 17 391 08 1125 18 375 09 1000 19 360 0A 900 1A 346 0B 818 1B 333 0C 750 1C 321 0D 692 1D 310 0E 642 1E 300 0F 600 1F 290 PB18 LPF 3141 100 [rad/s] 18000 [Pr. PB23] [Pr.
Positioning completed n.09 Speed feedforward 1 V/1000 min-1 n.0A Torque feedforward 1 V/100% rated torque n.0B Active gain *1 1st gain: 1 V 2nd gain: 2 V Gain type indicated by output voltage. n.0C Completion of position reference Completed: 5 V Not completed: 0 V Completion indicated by output voltage. n.0D External encoder speed 1 V/1000 min-1 Value at motor shaft 1.
Driver Inrush currents (A0-P) Main circuit power supply (L1 L2) Control circuit power supply (+24V 0V) LECSA2130A (Attenuated to approx. 5A in 5ms) 25A (Attenuated to approx. 0A in 4 to 6ms) Since large inrush currents flow in the main circuit power supply, always use no-fuse breakers and magnetic contactors. (Refer to section 11.5.)
Driver Inrush currents (A0-p) Main circuit power supply (L1, L2, L3) Control circuit power supply (L11, L21) LECSB138A (Attenuated to approx. 14A in 10ms) 20 to 30A (Attenuated to approx. 0A in 1 to 2ms) LECSB230A (Attenuated to approx. 5A in 10ms) Since large inrush currents flow in the power supplies, always use no-fuse breakers and magnetic contactors. (Refer to section 12.6.)
PD07 *DI3 3(CN6-3) CN6-3 PD06 000Ah 0 0 CN6-3 CN6-3 PD08 *DI4 4(CN6-4) CN6-4 PD06 000Bh 0 0 CN6-4 CN6-4 6 33 6 PD09 *DO1 1(CN6-14) CN6-14 0002h 0 0 CN6-14 CN6-14 () 00 OFF 02 RD 03 ALM 04 INP 05 MBR 06 DB 07 TLC 08 WNG 09 BWNG 0A SA 0C ZSP 0F CDPS 23 CPO 24 ZP 25 POT 26 PUS 27 MEND 38 1 PT0 39 2 PT1 3A 3 PT2 3B 4 PT3 3C 5 PT4 3D 6 PT5 3E 7 PT6 3F 8 PT7 .
PF _ _ ] 06: Parameter for manufacturer setting 07: Parameter for manufacturer setting 08: Parameter for manufacturer setting 09: Parameter for manufacturer setting 0A: Parameter for manufacturer setting 0B: [Pr. PL _ _ ] 0C: [Pr. PT _ _ ] 0E: [Pr.
Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRS090 Series 4.5 Message configuration 4-9 HRX-OM-T004 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to read or write register
Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Read Data1 Byte Count Hi Lo 30 32 30 30 45 45 HRSH Series 4.5 Message configuration 4-9 HRX-OM-R028 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to read or write register.
Driver Inrush currents (A0-p) Main circuit power supply (L1, L2, L3) Control circuit power supply (L11, L21) LECSC138A (Attenuated to approx. 14A in 10ms) 20 to 30A (Attenuated to approx. 0A in 1 to 2ms) LECSC230A (Attenuated to approx. 5A in 10ms) Since large inrush currents flow in the power supplies, always use no-fuse breakers and magnetic contactors. (Refer to section 13.5.)
Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRS Series 4.5 Message configuration 4-9 HRX-OM-M091 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to read or write register.
Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRSH Series 4.5 Message configuration 4-9 HRX-OM-Q033 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to read or write register.
Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 03 Function 03 Function 0 Head address of specified register 02 Quantity of bytes to read 0001 Quantity of register to read 00EE Information of 0h (circulating fluid discharge temperature: 23.8 oC) FB LRC 0C LRC Request message (Master to Slave) Start Slave Address Function Data LRC End 3A 30 31 30 33 46 42 0D 0A
. -99No.EX-OMA1023 Digital input unit (EX600-DX###) Index Name (Meaning) Type Value 40x0:0 Unit parameters UNSIGNED8 10 40x0:01 Monitor short circuit(power) Enum0800 0=Disable 1=Enable 40x0:05 Inrush current filter Enum0800 0=Disable 1=Enable 0=0.1 ms 1=1 ms 2=10 ms 3=20 ms 40x0:09 Input filtering time Enum0806 0=1 ms 1=15 ms 2=100 ms 3=200 ms 40x0:0A Input extension time Enum0807 40x1:0