SMC Corporation of America
Elite Part Number Search
Search Results "HRW008-H-D"

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: DNZ (D+N+Z)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: DZ (D+Z)

The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type).  Energy saving is substantially increased by exchanging cooling water and heat directly.  The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER, OTHERS, HRZ- THERMO CHILLER, 2X, HRZ - NO SIZE RATING, 374.78584 lb

The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type).  Energy saving is substantially increased by exchanging cooling water and heat directly.  The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly

reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90 °C, Cooling capacity: 2 kW, 8 kW, 15 kW, and 30 kW, Temperature stability: ±0.3 °C, Ideal for ordinary temperature and high temperature processes, Front Panel for HRW008

The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type).  Energy saving is substantially increased by exchanging cooling water and heat directly.  The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: Z (Circulating Fluid Automatic Recovery)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: N (NPT Fitting)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: CN (C+N)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: CNZ (C+N+Z)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: NZ (N+Z)

Cooling Capacity: 8 kW, Type: Fluorinated Fluid, Pump Inverter Control: None, Option: Circulating Fluid Automatic Recovery