Product Information » New Products Search Results
/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250-W-20/40. 8-17 8.5 Pump Capacity
40 28.4 7.5 11 12 KQ2T12-00A 18.5 23 32.3 17 10.7 8 4.2 57.4 45.4 9 15.7 16 KQ2T16-00A 23.8 28.6 40.5 20.6 13.4 8 4.2 100 58.9 13 29.8 Q Q 2 x O 2 x N M Q L1 L2 Q D D L1 M L1 M Note) D is maximum diameter.
HRSE Power supply HRZ 40 3-phase 380 to 415 VAC (50/60 Hz) Specifications HRZD Model HRSH100-Wl-40-l HRSH150-Wl-40-l HRSH200-Wl-40-l HRSH250-Wl-40-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.45 1.95 1.95 1.95 Control method PID control Ambient temperature/Altitude Note 1), 8) C Temperature: 2 to 45, Altitude: less than 3000 m HRW HECR Circulating
fluid flow rate [L/min] Circulating fluid flow rate [L/min] [m] [MPa] [m] [MPa] HRL300-Am-40 (CH1) HRL100/200/300-Am-40 (CH2) 0.6 0.9 90 60 0.8 80 0.5 50 0.7 70 Circulating fluid outlet 0.6 0.4 60 40 Usable flow rate range Circulating fluid outlet 0.5 50 0.3 30 0.4 40 0.3 0.2 30 20 Usable flow rate range 0.2 20 Circulating fluid return port Circulating fluid return port 0.1 10 0.1 10 0 0
m Circulating uid Note 1), 2) Tap water, 15 to 40% Ethylene glycol aqueous solution, Deionized water Set temperature range Note 1) C 5 to 35 Cooling capacity Note 3), 9) kW 10.5 15.7 20.5 25 28 Heating capacity Note 4) kW 2.5 3 5.5 7.5 Temperature stability Note 5) C 0.1 Circulating uid system Rated ow (Outlet) L/min 45 (0.43 MPa) 45 (0.45 MPa) 125 (0.5 MPa) Maximum ow rate L/min 120 130
Cooling Capacity: 200 (20.6kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting)
Cooling Capacity: 20.6kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: -
Cooling Capacity: 200 (20.6kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 200 (20.6kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: K (w/Fluid Fill Port)
Cooling Capacity: 200 (20.6kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKTW (A + K + T + W)
Cooling Capacity: 20.6kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 20.6kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: w/Fluid Fill Port
Cooling Capacity: 20.6kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K + T + W
Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH200-A-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH200-W-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
Cooling Capacity: 200 (20.5kW), Thread: Rc, Option: M (Applicable to DI Water Piping)