Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250-W-20/40. 8-17 8.5 Pump Capacity
The auto drain port comes with 3/8" One-touch fitting (applicable to the AFM30-A/40-A, AFD30-A/40-A). Note 2) Drain guide is G1/8 (applicable to the AFM20-A, AFD20-A) and G1/4 (applicable to the AFM30-A/40-A, AFD30-A/40-A). Note 3) A bracket is not assembled and supplied loose at the time of shipment.
If the voltage increase ratio (dV/dt) at the zero cross should exceed 40 V/200 msec., it may result in malfunction.
/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt xing brackets 2 pcs. (including 6 M8 bolts) Note 10) Weight (dry state) kg Approx. 180 Approx. 215 Approx. 280 Note 1) When the ambient temperature or circulating uid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 186-1).
Cooling Capacity: 150 (15.7kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AT (A + T)
Cooling Capacity: 15.7kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + T
Cooling Capacity: 150 (15.7kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting)
Cooling Capacity: 15.7kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: -
While maintaining the upstream pressure at a fixed value above 0.3 MPa, measure the max. flow to be saturated initially. Next, measure this flow rate at 80%, 60%, 40%, and 20%, as well as the upstream and downstream pressure. The sonic conductance C can be calculated based on this max. flow rate.
mA or less 80 mA or less 5 to 40 mA Load current 0.8 V or less 1.5 V or less (0.8 V or less at 10 mA load current) Internal voltage drop 4 V or less 100 A or less at 24 VDC Leakage current 0.8 mA or less at 24 VDC Red LED lights when ON.
Cooling Capacity: 150 (15.7kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: K (w/Fluid Fill Port)
Cooling Capacity: 150 (15.7kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 15.7kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: w/Fluid Fill Port
Cooling Capacity: 15.7kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Note 2) Moment caused by the impact load equivalent at the stroke end (at the time of impact with stopper). Note 3) Depending on the shape of the workpiece, multiple moments may occur. When this happens, the sum of the load factors () is the total of all such moments. 50 40 50 40 5 30 30 MY1C63 MY1C63 MY1C63 MY1C63 4 Load weight (kg) Load weight (kg) Load weight (kg) 2.