There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
(C) Correction factor 1.25 1.11 1 0.90 0.63 2 to 25 30 32 35 40 2 to 25 30 32 35 40 45 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 Note) For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45C.
HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250-W-20/40. 8-17 8.5 Pump Capacity . 8-18 8.5.1 HRSH100-A-20/40-, HRSH100-W-20/40. 8-18 8.5.2 HRSH150/200-A-20/40-HRSH150/200/250-W-20/40. 8-18 8.5.3 HRSH250/300
40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example
Distance 2,000 km 1,000 km 500 km Model LEY25mA LEY25mB LEY25mC Distance 2,500 km 1,200 km 600 km Model LEY32A LEY32B LEY32C Distance 4,000 km 2,000 km 1,000 km Model LEY16mA LEY16mB LEY16mC Items for belt check Stop operation immediately and replace the belt when belt appear to be below.
VM SUP blocking disk assembly SY30M-40-2A SY50M-40-1A SY70M-40-1A EXH blocking disk assembly Series SY3000 SY5000 SY7000 SY30M-40-1A SY50M-40-1A SY70M-40-1A XT34 Label for blocking disk If the blocking disk assembly is ordered using the manifold specification sheet and ordered at the same time as the manifold, the position where the blocking disk assembly is inserted will be labeled and
Positioning pin (Mounting reference plane) Model Distance LEFS25 H 4100 km LEFS25 A 2500 km LEFS25 B 1200 km Model Distance LEFS32 H 6000 km LEFS32 A 4000 km LEFS32 B 2000 km Positioning pin (Mounting reference plane) Positioning pin (Housing B bottom) Model Distance LEFS40 H 6000 km LEFS40 A 4000 km LEFS40 B 2000 km Body mounting reference plane Positioning pin The traveling parallelism
both solenoids located at one end SX Type 41P manifold SX3*40 (Cv=0.22) SX5*40 (Cv=0.53) VQ1*11 (Cv=0.3) VQ plug lead types External pilot valves required SX3*40 (Cv=0.22) SX5*40 (Cv=0.53) SX7*40 (Cv=0.9) VQ0*51 (Cv=0.15) SY3*40 (Cv=0.22) SY5*40 (Cv=0.53) VQ0*51 (Cv=0.15) SY3*40 (Cv=0.22) SY5*40 (Cv=0.53) SY7*40 (Cv=0.9) SX Type 42P manifold Non plug-in valves Porting: Body ported or true
Applicable tubing Connection thread 15-2-41 1 One-touch Fittings Manifold Series KM Compact piping possible. Manifold piping possible. Many varieties (40 types) are available. One-touch fittings give the most efficient operation.
Series SUP blocking disk assembly EXH blocking disk assembly SY3000 SY30M-40-1A SY30M-40-2A SY5000 SY50M-40-1A SY50M-40-1A SY7000 SY70M-40-1A SY70M-40-1A MLabel for blocking disk Label to indicate and confirm on the manifold where the SUP/EXH blocking disk assemblies were inserted. (3 sheets each) * If the blocking disk assembly is ordered using the manifold specification sheet and ordered
Do not use in an atmosphere containing an inflam mable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold. However, do not order an EXH block base assembly because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base assembly because it is not attached to the spacer.
Mixed single and double wiring is available as an option.
Also, when wiring is not required for a station that is to be mounted with an option such as an individual SUP spacer, enter an "X".
How to Order Consult SMC. 2.1-29 One-touch Fittings Manifold Series KM Model Compact piping. Many varieties (40 types) available. One-touch fittings give the most efficient operation.
COM COM Conductor resistance /km, 20C 65 or less Note) Mounting valve has no polarity. It can also be used as a negative common. Voltage limit V , 1 min, AC 1000 SpecialWiring Specifications (Option) [-K] Insulation resistance M/km, 20C 5 or more Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids.
Refer to page 120 for an order example.
An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold. However, do not order an EXH block base assembly because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base assembly because it is not attached to the spacer.
In such a case, give an additional tightening to the tube connection part. If leakage still occurs after giving an additional tightening, replace the fitting with a new product. For other precautions, refer to Fittings & Tubing Precautions. When using the fluoropolymer fittings, refer to the precautions on pages 445 and 446. Select the size after confirming O.D. and I.D.